background image

6

Ultra-Aire XT155H Installation Instructions

www.Ultra-Aire.com | 1-800-533-7533

Important Precautions

•  The device is designed to be installed indoors in a space that is protected from rain and flooding. 
• Install the unit with enough space to access one of the side panels for maintenance and service.
• Avoid directing the discharge air at people. 
•  If used near a water source; be certain there is no chance the unit could fall into the water or get splashed and 

that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet. 

• DO NOT use the dehumidifier as a bench or table. 
•   DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted 

noise may result. Place the Ultra-Aire XT155H on supports to raise the base of the unit.

•  A drain pan MUST be placed under the dehumidifier if installed above a living area or above an area where  

water leakage could cause damage.

Location Considerations

•  Allow sufficient clearance to handle the unit’s overall dimensions as well as the necessary return and supply 

ductwork to the unit. 

• Allow sufficient clearance for filter removal and to prevent airflow obstruction.
•  Electrical service access will require the removal of a side panel. Allow sufficient clearance on a side of the unit.
•  Locate the dehumidifier in an area where the cord’s length (9') easily reaches a 115 VAC electrical outlet with a 

minimum of a 15 Amp circuit capacity.

• Locate the dehumidifier in an area where field wiring the control (low voltage) to the unit will be possible.
•  It is recommended that a  

backdraft damper be used in 
the discharge duct of the  
Ultra-Aire XT155H, especially  
when connecting to the supply 
ducting system. The backdraft 
damper prevents supply air 
from counter flowing through 
the Ultra-Aire XT155H when  
it is not operating. The  
dehumidifier’s location should 
be chosen to allow installation 
of this accessory if necessary.

•  The Ultra-Aire XT155H may 

be suspended from structural 
members with steel hanger 
straps or a suitable alternative, 
ensuring the assembly  
supports the dehumidifier’s 
base in its entirety. DO NOT 
hang the Ultra-Aire XT155H 
from its cabinet.

•  Allow for proper routing and 

drainage of needed drain pipes.

Electrical Service Access

(Either Side)

Filter

9' Power Cord

Top View

Minimum
Clearance
For Filter
(Either Side)

15" 

6" Fresh Air Intake (Optional)

10" Return Air Duct

10" Supply Air Duct

A

B

C

32 3/8"

With Collars Installed

26"

Without Collars Installed

B

C

Drain Port

A

Top View

32 3/8"

With Collars Installed

26"

Without Collars Installed

Drain Port

9' Power Cord

Filter

Minimum

Clearance

For Filter

(Either Side)

20" 

6" Fresh Air Intake (Optional)

10" Return Air Duct

A

B

6” Fresh Air 

Intake (Optional)

10” Return Air Duct

Electrical Service Access

(Either Side)

A

B

The 10” Supply Air Duct (not pictured) is 
below the Fresh Air Intake and the Return
Air Duct. The same amount of clearance 
is needed for the 10” Supply Air Duct.

DEHUMIDIFIER SET UP

Summary of Contents for 4031070

Page 1: ...mate in comfort health and property protection through Dehumidification Fresh Air Ventilation Optional Air Filtration TS 693 3 24 16 P N 4031070 Serial No Install Date Sold by HVAC Installer Please Le...

Page 2: ...12 Recommended Multiple HVAC Systems Installation 13 No Existing Ductwork Installation 14 Fresh Air Ventilation 15 Determine Ventilation Requirements 16 Controls 17 Air Filtration 19 MERV Rating Char...

Page 3: ...ALLATION MAY CAUSE PROPERTY DAMAGE OR INJURY INSTALLATION SERVICE AND MAINTENANCE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN DEHUMIDIFIER IS HEAVY HANDLE WITH CARE AND FOLLOW INSTALLATION INS...

Page 4: ...onnections 6 Round Inlet 10 Round Inlet 10 Oval Outlet Air Filter MERV 11 Standard Pleat Efficiency 65 ASHRAE Dust Spot Size 16 x 20 x 2 Optional Air Filter MERV 14 Embossed Pleat will need filter hou...

Page 5: ...Flex Duct 25 4022126 10 Flex Insulated Duct 25 4028399 10 Oval to Round Adapter Items Included in Box Ultra Aire XT155H Dehumidifier Ultra Aire XT155H Installation Instructions Ultra Aire XT155H Level...

Page 6: ...ire the removal of a side panel Allow sufficient clearance on a side of the unit Locate the dehumidifier in an area where the cord s length 9 easily reaches a 115 VAC electrical outlet with a minimum...

Page 7: ...duct to the unit using the screws provided The 6 duct should be capped if fresh air is not desired If setting up the unit to provide fresh air ventilation see page 17 Return Air Inlet Attach 10 diame...

Page 8: ...AT DEFROST RUN CAPACITOR RED 6 YEL 5 R S 3 BLK 11 GRN 4 GRN 4 BLK 1 WHT 5 115V 220V COMPRESSOR 2 1 3 4 BLK 3 WHT 6 A B B A BLK 7 COM COM 24V LINE NEUTRAL NC NO ELECTRICAL REQUIREMENTS CAUTION DO NOT A...

Page 9: ...automatically pumped to a remote location when the water level in the pump s reservoir rises to close the float switch The pump also contains a safety float switch The white leads from this switch ex...

Page 10: ...to reduce noise and vibration transmitted to rigid ductwork in the structure Use a minimum 10 diameter round or equivalent rectangular duct for total duct lengths of up to 25 Use a minimum 12 diamete...

Page 11: ...e to select one to disconnect from the existing HVAC system and use it for the dedicated Ultra Aire XT155H return Select a return from a central location in the house that is always open to the rest o...

Page 12: ...on when the dehumidifier is in operation Create a separate return for the Ultra Aire XT155H in a central area of the building Installing the supply air from the Ultra Aire XT155H to the return of the...

Page 13: ...entral location HVAC systems should be in close proximity for optimal air flow For multiple systems contact Technical Support at 1 800 533 7533 DUCTING TO HVAC SYSTEMS Recommended Multiple HVAC System...

Page 14: ...etc Be sure to utilize multiple rooms to allow air inside the structure to properly circulate Proper air distribution is important to ensure even humidity control and heat distribution throughout the...

Page 15: ...otorized damper is used a digital control is required It may be necessary to use 8 duct work if additional fresh air is required In cold climates or at times when the dew point is low ventilation can...

Page 16: ...CFM ____________ FRESH AIR VENTILATION Determine Ventilation Requirements The MINIMUM ventilation requirement is calculated using ASHRAE 62 2 2010 Use one or both of the options below to determine you...

Page 17: ...HE TRANSFORMER WILL RESULT Control Connections The control and the control wires leaving the Ultra Aire XT155H are numbered and color coded to prevent confusion Depending on the control some of the wi...

Page 18: ...ower transformer neutral side common with red Yellow Transformer high side Five Color Coded Wires Control Operation Unit ON Fan ON Make contact between yellow and blue wires Unit OFF Fan On Make conta...

Page 19: ...Release the latch from the cabinet by pulling it down and out Remove the filter door by pulling it out of the bottom tab Step 2 Remove the filter by gently pulling it straight out of the unit Insert...

Page 20: ...l Bag Filter Nonsupported Legionella microfine fiberglass or 11 60 65 95 Humidifier Dust Better Commercial Buildings synthetic media 12 36 in deep 6 12 pockets Lead Dust 10 50 55 95 Milled Flour Box F...

Page 21: ...s left in the system it must be recovered before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type SERVICE Service Parts List Item Part No Descr...

Page 22: ...ires together only the fan should run Disconnect the wires 8 Connect the yellow and blue wires together fan and compressor should run Disconnect the wires 9 If this test works then the field control w...

Page 23: ...grees or below and or in area of low relative humidity the dehumidifier will produce little to no water 7 Collecting the water removed in a 24 hour period will give a measurement of performance WARNIN...

Page 24: ...ot cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Custom...

Page 25: ...25 www Ultra Aire com 1 800 533 7533 Ultra Aire XT155H Installation Instructions...

Page 26: ...26 Ultra Aire XT155H Installation Instructions www Ultra Aire com 1 800 533 7533...

Page 27: ...27 www Ultra Aire com 1 800 533 7533 Ultra Aire XT155H Installation Instructions...

Page 28: ...1 800 533 7533 www Ultra Aire com...

Reviews: