1. Intended Application ...................................................... 2
2. Registration ................................................................... 2
3. Specifications     ............................................................ 3
4 . Installation .................................................................... 3

4.1 Location .................................................................... 3

4.1A No Ducting ............................................................ 3
4.1B Duct Inlet and Outlets Ducted ............................... 3
4.1C Remote Area w/Outlets Ducted ............................. 3
4.1D Remote Area w/Inlets Ducted ................................ 4

4.2 Electrical Requirements ............................................. 4
4.3 Condensate (Water) Removal ..................................... 4

5. Ducting .......................................................................... 4

5.1 Optional Ducting Kit ................................................... 4
5.2 Ducting for Dehumidification ..................................... 4

6. Operation ....................................................................... 5

6.1 Humidity Control Adjustment ..................................... 5
6.2 Blower (Fan) Switch .................................................. 5

7. Maintenance .................................................................. 5

7.1 Air Filter..................................................................... 5

8. Service .......................................................................... 5

8.1 Technical description ................................................. 5
8.2 Troubleshooting ......................................................... 6
8.3 Defrost Thermostat .................................................... 6

9. Service Parts List ........................................................... 6
10. Accessory/Replacement Parts List ............................... 6
11. Optional Remote Humidity Control ............................... 7
12. Wiring Diagram ............................................................ 7
Warranty ............................................................................ 8

Precautions

•  Do not operate the Santa Fe

 Max Dry Dual XT with a cut 

or frayed power cord.

•  Do not unplug the unit by pulling on the cord. Grasp the 

plug firmly and pull it out of the wall socket or power 
receptacle.

• Always use a grounded outlet.
•  Never operate electrical equipment near or in standing 

water.

•  Do not stick your fingers or other objects through the safety 

grill.

•  When changing filters, do not stick fingers or other objects 

in the unit.

•  No user serviceable components. Contact installer or call 

1-800-533-7533 for all repair or warranty needs.

•  Do not restrict airflow in to or out of the unit. This may 

cause the unit to overheat.

•  The unit should never be serviced or cleaned while it is 

plugged in.

• Do not sit or stand on the unit, or use as a shelf or table.
•  Before leaving the unit unattended, ensure children do not 

have access to the equipment. Do not allow children to play 
with or near the unit or in its air flow.

•  The unit is designed to be installed indoors only.

Read the installation, operation and maintenance 
instructions carefully before installing and using this 
unit. Proper adherence to these instructions is essential 
to obtain maximum benefit from your Santa Fe Max Dry 
Dual XT dehumidifier.

Read and Save These Instructions

 WARNING!

 

— This symbol means important 

instructions. Failure to heed them can result in serious 
injury or death.

 CAUTION!

 

— This symbol means important 

instructions. Failure to heed them can result in injury or 
material property damage.

1. Intended Application(s)

The Santa Fe Max Dry Dual XT is intended for use in 
crawlspaces or basements: however, the unit can be placed 
in almost any residential setting where dehumidification is 
desired. Use in non-residential applications and pool areas 
may void warranty.

The Santa Fe Max Dry Dual XT is designed to operate in 
temperatures between 45° and 95°F. This unit works most 
effectively between 56° and 95°.

In order to efficiently control humidity levels, the area in 
which the dehumidifier is to be operated must be free of 
water intrusion or excessive fresh (outside) air infiltration. 
Before installing the Santa Fe Max Dry Dual XT, water 
intrusion and air infiltration problems should be addressed.

2. Registrations

The Santa Fe Max Dry Dual XT conforms to UL STD 1995.

TABLE OF CONTENTS

2

Santa Fe Max Dry Dual XT Installer’s & Owner’s Manual

Summary of Contents for 4027450

Page 1: ...r com Free standing Moisture Control for Large Areas n High capacity n High efficiency n Environmentally friendly n Patent pending dual air distribution INSTALLER S OWNER S MANUAL HVAC INSTALLER PLEAS...

Page 2: ...ot sit or stand on the unit or use as a shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in...

Page 3: ...e exhaust of the unit within 1 of a wall or obstruction Do not place the unit near open water 4 1A No Ducting fig 1 The simplest installation is to place the Santa Fe Max Dry Dual XT with no ducting T...

Page 4: ...50 RH Use of a ground fault circuit interrupter GFCI protected circuit is recommended The unit should not be used in areas prone to flooding CAUTION For proper drainage the unit must be mounted so th...

Page 5: ...s with a standard MERV 6 efficient pleated fabric filter This should be checked every six months The pleated fabric filter can generally be vacuumed clean several times before needing replacement Oper...

Page 6: ...n capacitor n Blower runs with fan switch AUTO but compressor cycles on off 1 Low ambient temperature and or humidity causing unit to cycle through defrost mode 2 Defrost thermostat defective 3 Defect...

Page 7: ...7533 11 Santa Fe Max Dry Dual XT Optional Remote Humidity Control CAUTION This should only be performed by a qualified electrician A 120Vac remote humidity control is available from the factory This...

Page 8: ...er any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Res...

Page 9: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...

Reviews: