Free-standing Moisture Control for Large Areas

INSTALLER’S & OWNER’S MANUAL

HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER

Summary of Contents for 4025081

Page 1: ...1 08 For small usage P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales thermastor com Free standing Moisture Control for Large Areas INSTALLER S OWNER S MANUAL HVAC INST...

Page 2: ...80 F 60 RH Operating Temp 56 F min 100 F max Air Flow 323 CFM without external ducting 307 CFM 20 WG external static 285 CFM 40 WG external static Refrigerant Charge 1 lb 12 oz R22 Duct Connections Ro...

Page 3: ...air flow path between the two rooms e g high door undercut louvered door or wall grill This eliminates the need to remote mount the humidity control WARNING Before installing the dehumidifier in the...

Page 4: ...Route the drain hose through the trap as shown below in Figure 6 Position the trap on the hose approximately 12 away from the unit 4 Ducting 4 1 Optional Ducting Kit 10 collars may be attached to acc...

Page 5: ...to the options and accessories table in this document 6 2 Blower Oiling The blower motor has been lubricated at the factory for many years of normal operation 7 Service WARNING Servicing the Santa Fe...

Page 6: ...charge 3 Dirty air filter or air flow restricted 7 3 Defrost Thermostat The defrost thermostat is attached to the refrigerant suction tube between the accumulator and compressor It will automatically...

Page 7: ...SANTA FE HC OWNER S AND INSTALLER S MANUAL 7 Santa Fe HC Installer s Owner s Manual 10 Wiring Diagram...

Page 8: ...de panel of the dehumidifier by removing 9 hex screws Remove four screws on back of unit to expose electbox 4 Remove the 4 screws securing the wiring box to the inside of the blower end of the dehumid...

Page 9: ...shown STEP 2 Pre drilled mounting holes are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealin...

Page 10: ...applies to residential applications and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper re...

Page 11: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...