THERM PRO TP-15H Instruction Manual Download Page 2

Calibration

The thermometer comes with a Calibration feature. In most cases, the 
thermometer was calibrated precisely at our manufacturing facility, and 
generally you do NOT need to calibrate the thermometer. However, after a long 
period of use and you believe that the temperature reading displayed by the 
thermometer is not accurate, you may follow the process below to re-calibrate 
the thermometer:

1. Use distilled or purified water to make ice cubes in your refrigerator;

2. Get a thermal insulated bottle. If you don’t have one, use a beaker or a regular 
    cup;

3. Fill the bottle with ice cubes (no less than 70% of the volume), then top off with 
    cold distilled or purified water (no greater than 30% of the volume);

4. Stir the mixture and let it sit for 10 minutes to allow the ice and water to reach 
    its temperature equilibration;

5. Turn on the thermometer and hold the LOCK/CAL button for 5 seconds to enter 
    Calibration mode. CAL will begin flashing for a few seconds and then the 
    current temperature reading will begin to flash which means the thermometer 
    is in Calibration mode;

6. Immerse the probe in the ice/water mixture and make sure not to touch the 
    sides of the container. Wait till the temperature reading drops to its lowest 
    value, which should be around 32°F or 0°C. If the temperature of the ice/water 
    mixture is not within 28°F to 36°F (or -2°C to +2°C), the calibration can’t be 
    continued: you will need to follow the above steps to re-make the ice/water 
    mixture;

7. Hold the LOCK/CAL button for 3 seconds to confirm the calibration and exit
     the Calibration mode.

Note:

The Calibration mode will only last for 15 seconds. If you’re unable to finish the 
calibration within 15 seconds, the thermometer will automatically exit 
Calibration mode.

Undo-Calibration

If you want to undo the calibration and go back to the default calibration setting, 
please follow the below steps:

1. Turn on the thermometer and hold the LOCK/CAL button for 5 seconds to enter 
    Calibration mode;

2. When you see temperature reading begins flashing, press and hold the Light 
    button for 3 seconds. The temperature reading will stop flashing and the 
    calibration is set to the default setting.

Helpful hints

When measuring multiple or different foods and meats, it may be desirable to 
cool the probe by rinsing the tip with cold water between readings.

It is recommended that you wipe the probe tip clean between readings. This is 
especially important when taking readings from different foods and meats.

The thermometer is designed for temporary, hand held use. Do not use in an 
oven. Do not leave inserted in extremely hot foods or liquids (anything over 
572°F) for more than 1 minute.

-4-

-5-

Always take your reading in the thickest available portion of meat. Thin 
portions of meat are difficult to measure because they tend to cook through 
fast. Avoid touching bone. If the tip touches the bone or heavy fat area of the 
meat, or if the tip is not deep enough, take a second reading to ensure 
accuracy.

Not intended for use by persons ages 12 or under.

Care of your thermometer

Do not touch the stainless portion of the thermometer during or right after 
measuring temperatures since it will be hot.

Do not leave exposed to extreme high or low temperatures as this will damage 
electronic parts and plastics.

Do not leave the thermometer inserted in food during cooking.

-6-

Limited one-year warranty

ThermoPro warrants this product to be free of defects in parts, materials and 
workmanship for a period of one year, from date of purchase.

Should any repairs or servicing under this warranty be required, contact Customer 
Service by phone or email for instructions on how to pack and ship the product to 
ThermoPro.
This warranty gives you specific legal rights and you may also have other rights 
which vary from state to state.

Customer service

Telephone: 1-877-515-7797(USA & Canada only)

Email: [email protected]

Hours: Weekdays 8:00 AM - 8:00 PM EST(USA & Canada only)

Our website: www.buythermopro.com

Remove battery if stored for more than four months.

Keep unit away from children. The unit or parts of the unit might be a choking 
hazard.

Dispose of the unit legally and recycle when possible.

Do not remove any screws.
Do not dispose this unit in a fire. IT MAY EXPLODE.

Do not immerse the unit in water.

Do not subject the unit to excessive force, shock, dust, temperature or humidity.

Disposal

You can help protect the environment! Please remember to respect the local 
regulations. Hand in the non-working electrical equipment to an appropriate 
waste disposal center.