Battery
S-Pack 700
S-Pack 1200 S-Pack 1400
Charging time
~3h30
~5h00
~6h00
Note that at half time of the charging time men-
tioned on table above, the battery is already charged
at around 75% of its maximum capacity (fast char-
ging process). Lab test done using Therm-ic USB wall
plug universal charger (optional).
SAFETY FUNCTIONS
• Short circuit protection: If a short circuit occurs on
the connector or heating element, the integrated
electronic circuit switches off the S-Pack battery.
After removal of the short circuit and brief insertion
into the charging shaft, the S-Pack battery is ready
for use again.
the LED on the charge indicator (2.2) will switch
back to green.
3. LED blinking on USB S-Pack charger between
green and red when charge above 95%. LED stays
green when fully charged.
4. Remove both S-Pack batteries from the charging
shaft.
5. After the S-Pack batteries have been charged, they
are automatically in POWER OFF mode.
Important note:
• Recharge the S-Pack battery after each use. This
extends the service life of the batteries and ensures
that the device is always ready for use.
• The battery consists of lithium ion cells and can be
charged in any state. For this reason, the battery
does not need to be fully discharged before
charging.
• When starting the charging process, the S-Pack
battery can be in any operating mode (POWER
OFF, IN USE)
• The full charging capacity of the S-Pack battery can
only be conserved if the S-Pack battery are remo-
ved from the charging station after the charging
procedure is complete.
Charging times: