background image

Art. no.: A003-928_Rev 01 
Last edited: CW40/2014 

9

 

 

 

FEEDBACK SENSOR INCL. TOUCH KEY 

                   USER MANUAL 

 

 

Note 

 
 

5.3  Options

 

 

Available option:  

 

USB charger for feedback sensor 

 

The  feedback  sensor  incl.  touch  key  can  only  be  used  in  combination  with  the 
suitable  THERA-Trainer  software,  a  control  and  display  unit,  and  a  Bluetooth 
receiver for sensors.

 

 

 

5.4  Removable parts  

 

 

Name 

Article no.

 

 

 

USB charging cable 

A003-891 

 
 
 
 
 
 
 
 
 
 
 
 

USB charger for 
feedback sensor 

A003-980 

 
 
 
 
 
 

Bluetooth receiver for 
sensors 

A004-020 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TT-SENS-14-01

Page 1: ...FEEDBACK SENSOR INCL TOUCH KEY MODEL TT SENS 14 01 USER MANUAL English translation of original user manual...

Page 2: ...et to know your feedback sensor incl touch key better It takes you safely through the functions and use of your new feedback sensor incl touch key and also offers plenty of tips and advice for getting...

Page 3: ...h receiver for sensors 7 4 Switching on THERA Trainer software 8 OPERATION 11 8 1 Charging the battery 11 8 2 Switching on off the feedback sensor incl touch key 13 8 3 Establishing a connection 13 8...

Page 4: ...on warns of the risk of material damage Warning warns of the risk of physical injury Danger warns of the risk of fatal injury Structure of warnings Type and source of danger Action to avoid the danger...

Page 5: ...household waste Dispose of the product in accordance with local regulations Type BF medical device IP22 Protection against solid foreign objects with a diameter greater than 12 5 mm Protection against...

Page 6: ...m range of movement must not overstrain the user Only use the feedback sensor incl touch key if in good and functional condition In case of damage malfunctions etc of the feedback sensor incl touch ke...

Page 7: ...incl touch key Specialised staff Persons who gained their skills and expertise by means of professional training in the medical or medical technical sector e g doctors therapists specialist dealers Pe...

Page 8: ...kits etc These can influence the device and should therefore be kept at a distance of 3 8 m 5 SCOPE OF DELIVERY AND EQUIPMENT The feedback sensor incl touch key comes with individual options This use...

Page 9: ...for feedback sensor The feedback sensor incl touch key can only be used in combination with the suitable THERA Trainer software a control and display unit and a Bluetooth receiver for sensors 5 4 Remo...

Page 10: ...IEW 1 Sensor orientation 2 Touch key with touch pad 3 Sensor detection here feedback sensor incl touch key Type A 4 Socket for USB charging cable 5 Feedback sensor incl touch key applied part Type BF...

Page 11: ...to a THERA Trainer balo using the feedback sensor mounting kit for the THERA Trainer balo To fix it follow the instructions below Mount the sensor holder 1 to the system bracket 3 with two bolts 2 us...

Page 12: ...er 4 to the system bracket 2 with two bolts 3 using a suitable tool Fix the sensor holder on the system bracket using the correct orientation wider side facing left Insert two bolts through the holes...

Page 13: ...THERA Trainer software will be interrupted and can only be restored by restarting 7 4 Starting THERA Trainer software Switch on control and display unit THERA Trainer software starts automatically Wh...

Page 14: ...discharge protection for the battery When the battery is discharged When the remaining charge based on the capacity still available is under 30 the activation charge status LED will flash green orang...

Page 15: ...a medical device USB charging cable and USB charger Charging must take place outside a 1 5 metre radius of the direct surrounding of the patient Charging process begins The LED of the charge activatio...

Page 16: ...der to establish a wireless connection a Bluetooth receiver for the sensors must be plugged into the control and display unit Only use the Bluetooth receiver for sensors approved by the manufacturer a...

Page 17: ...indicator flashes red The control and display unit shows the error code Observe the user manual for the relevant THERA Trainer software The software version of the feedback sensor incl touch key is r...

Page 18: ...dback sensor incl touch key must always be disconnected from the mains before cleaning and disinfecting Make sure that no cleaning agent or disinfectant gets into the feedback sensor incl touch key If...

Page 19: ...h key is suitable for further use by a different customer Before the feedback sensor incl touch key is reused Clean and disinfect thoroughly see chapter 10 Cleaning and disinfection Perform a visual c...

Page 20: ...tive poles have been taped up Feedback sensor incl touch key Dimensions l x w x h approx 7 5 cm x 5 5 cm x 2 5 cm Weight approx 80 g Protection category IP22 only if the feedback sensor incl touch key...

Page 21: ...alue at 10 m distance AC mains power supply Wired interference 0 15 0 5 66 dB uV to 56 dB uV quasi peak value CISPR 11 56 dB uV to 46 dB uV mean value The limit values decrease linearly with the logar...

Page 22: ...0 4 11 0 5 period test voltage level 5 Ut 5 periods test voltage level 40 Ut 25 periods test voltage level 70 Ut A Voltage interruption 5 duration 5 s C Fast transients EN 61000 4 4 2 kV A Surge volta...

Page 23: ...ienced radio TV technician for help 14 5 Statement acc RSS Gen Issue 3 Sect 7 1 3 This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two cond...

Page 24: ...ntechnik GmbH Blumenweg 8 88454 Hochdorf Germany Phone 49 7355 93 14 0 Fax 49 7355 93 14 15 E Mail info thera trainer de Internet www thera trainer de Article no A003 928_Rev 01 Last edited CW40 2014...

Reviews: