Please read these instructions thoroughly before use. Failure to follow instructions may result in 

equipment damage or failure, losses, injury or death.

 DANGER: 

To avoid possible electric shock:
  •  If the power cord has been damaged, DO NOT operate, SuperFlo™ Pump should be replaced. 
  •  If the power cord lead has been damaged, DO NOT operate, SuperFlo™ Pump should be replaced. 
  • Close supervision is necessary when the unit is used near children.

 WARNING: 

To reduce the risk of electric shock:
  •  Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit 

Interrupter and never remove the ground pin from the plug. 

  •  Provide a “drip loop” for the power cord. This is a loop in the cord below the level of the receptacle or 

plug that prevents water from traveling along the cord in the direction of the receptacle. 

  •  ALWAYS unplug the SuperFlo™ Pump from power source when it is not in use, and before installing, 

removing or servicing the SuperFlo™ Pump components.

  • DO NOT immerse the SuperFlo™ Pump plug in water or attempt to use a wet plug. 
  •  The SuperFlo™ Pump is NOT suitable for use in swimming pools, swimming ponds, or other 

situations where bodily contact is made with the water. 

 CAUTION: 

To reduce the risk of equipment damage or failure:
  •  DO NOT place SuperFlo™ Pump near flammable or other dangerous materials or objects.
  • DO NOT use the SuperFlo™ Pump for fluids other than water.
  •  ALWAYS unplug the unit if there is no water running through it to prevent over heating.
  • ALWAYS operate the pump completely submerged for proper cooling.
  •  DO NOT operate during freezing conditions. Drain SuperFlo™ Pump and store in a protected 

location. 

  

The Pond Guy® is not responsible for equipment damage or failure, losses, injury or death resulting 

from failure to follow safety precautions, misuse or abuse of equipment.

thepondguy.com  |  866-POND-HELP (766-3435)  

2

Summary of Contents for SuperFlo 9000

Page 1: ... Product Manual TM ImportantInformation 2 TechnicalSpecs 3 4 InstallingYourSuperFlo Pump 4 5 CleaningYourSuperFlo Pump 6 ReplacementParts WarrantyInformation 7 AdditionalNotes 8 Table of Contents For Model SuperFlo 9 000 Item 120225 ...

Page 2: ...eptacle ALWAYS unplug the SuperFlo Pump from power source when it is not in use and before installing removing or servicing the SuperFlo Pump components DO NOT immerse the SuperFlo Pump plug in water or attempt to use a wet plug The SuperFlo Pump is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the water CAUTION To reduce the risk of eq...

Page 3: ...Adapter Nut Accommodates 3 Flex PVC Tubing B D A C Getting to Know Your SUPERFLO PUMP TECHNICAL SPECS MODEL POWER AMPS MAX FLOW MAX HEAD HEIGHT PLUMBING SIZE POWER CORD LENGTH SuperFlo 9000 120V 60 Hz 5 8 Amps 9 900 GPH 20 3 or 4 Flexible PVC Slip Adaptor Required for 3 Plumbing Included Check Valve and Rubber Coupler Recommended Not Included 50 Standard Longer Power Cords are Available 15425 Chet...

Page 4: ... a protected area Tools Required PVC Glue Primer TECHNICAL SPECS CON T Step 1 Remove End Caps REMOVE the protective power cord end caps and connect the power cord to the power lead Step 2 Attach Plumbing Submerge ATTACH plumbing to the pump discharge using PVC glue and primer The pump discharge is set up for 4 plumbing however 3 may be used with the included reducer fitting SUBMERGE the SuperFlo P...

Page 5: ...luded See image for reference To ensure proper function please reference arrows on your check valve during installation Rubber Coupler Check Valve PVC Elbow Step 3 Waterfall CONNECT the plumbing to your waterfall filter or spillway Reference waterfall filter or spillway manual for proper installation Step 4 Plug In PLUG the power cord into a standard 120 volt GFCI protected outlet 15425 Chets Way ...

Page 6: ... TROUBLESHOOTING Pump does not turn on Check that the power cord is connected Check to see if the circuit breaker is tripped GFCI may be faulty Check power cord for damage Pump turns on and then shuts off Verify pump is completely submerged for proper cooling Check for debris clogging the pump intake Reduced water flow Check for debris clogging the pump pre filter Verify that the water level is no...

Page 7: ...Y All SuperFlo Pumps carry a 2 year warranty The Pond Guy will repair or replace any units found to be defective This limited warranty is extended exclusively to the original purchaser and begins from the date of original purchase receipt Abuse or misuse of this product or power cord alterations void all warranty Please call for a Return Authorization Number prior to returning product by calling o...

Page 8: ...View other great products on line at www thepondguy com THANK YOU FOR CHOOSING ThePondGuy Inc WeKnowPonds 15425 Chets Way Armada MI 48005 866 POND HELP 766 3435 thepondguy com ADDITIONAL NOTES 510467 V2 ...

Reviews: