Theben TIMEGUARD PDSM362AB Installation & Operating Instructions Manual Download Page 2

1. General Information

These instructions should be read carefully and retained for 
further reference and maintenance.  

Timeguard reserve the right to alter these instructions 

 at any time. Up to date instructions will always be available 
for download at www.timeguard.com 

2. Safety

• Before installation or maintenance, ensure the mains supply
   to the PIR is switched off and the circuit supply fuses are 
   removed or the circuit breaker turned off.  
• It is recommended that a qualified electrician is consulted or
   used for the installation of this PIR and install in accordance 
   with the current IEE wiring and Building Regulations.  
• Check that the total load on the circuit including when this
   PIR is fitted does not exceed the rating of the circuit 
   cable, fuse or circuit breaker.  
• To clean use a clean dry cloth only. Do not use liquid cleaners.

3. Technical Specifications

•  Class Protection:                  Class 2  

Note:

•  IP Rating:  

               IP54 

•  Operating Temperature:      

 

-20

˚

 to 40

˚

C

•  PIR Detection Range:           

  

up to 8m at a 2.5m

•  Mains Suppply:                    220-240V AC 50Hz

1

mounting height

•  Dectection Angle:               

     

360

˚ 

Summary of Contents for TIMEGUARD PDSM362AB

Page 1: ...Presence Detector With 360 Surface Mount PIR Model PDSM362AB 1 Channel I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Optional Absence Detection...

Page 2: ...eaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR and install in accordance with the current IEE wiring and Building Regulations Che...

Page 3: ...Construction Polycarbonate Dimensions H x W x D 105mm x 105mm x 48mm PIR Ceiling Projection 48mm If a 2 channal surface PIR is required model number PDSMSB Surface Mount Box along with PDFM362AB 2 Ch...

Page 4: ...ensure the best performance from the PIR and the appointed approach path Effective Approach Path ACROSS Ineffective Approach Path TOWARDS Avoid positioning the PIR near any sources of heat in and aro...

Page 5: ...are removed or the circuit breaker turned off An isolating switch should be installed to enable the power to be switched ON and OFF to the PIR This allows the unit to be easily switched OFF for mainte...

Page 6: ...points on the base plate for the installtion required Pass the 230V 50Hz mains supply and load cables through the hole and prepare for termination Drill the holes and insert he rawl plugs into positio...

Page 7: ...ed to Neutral BlueorBlacktoN Locate the terminal connections and terminate the cables into the terminal block ensuring that the correct polarity is observed and that all bare conductors are sleeved Se...

Page 8: ...ion area when the PIR is triggered and the load will turn ON for the minimum set amount of time Once you are happy with the pickup area of the PIR you can set the Lux dial in the anticlockwise directi...

Page 9: ...ards as long as detection in the area has constant movement the PIR will continue to keep the luminaire or attached load swtiched on until the subject has moved out of the detection area and the time...

Page 10: ...IR10AB is an optional remote control that is sold separately If absence detection is required the IR10AB will be needed to change modes over LUX control adjustment Auto mode only Time delay adjustmen...

Page 11: ...de of the UK All shipping costs are to be paid in advance before a replacement is sent Problem Cause Solution False activation Luminaire switches on for no apparent reason Heat sources as described in...

Page 12: ...com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query For a product brouchure please contact Timeguard Limited Victory Par...

Reviews: