background image

1

theLuxa S360 WH 

1010510

theLuxa S360 BK 

1010511

309699

Motion detector

EN

1.  Essential safety instructions

Danger of death through electric shock or fire!

 

Installation should only be carried out by a pro- 

    fessional electrician!

WARNING

 

The device conforms with EN 60669-2-1 when correctly  
installed

 

IP 55 in accordance with EN 60529

Designated use

 

Motion detector for automatic lighting control dependent 
on presence and brightness

 

Suitable for installation on external walls or ceilings

 

Suitable for entrances, garages, gardens, corridors, parks, 
etc.

 

Only intended for installation outside of arm‘s reach

Disposal

Dispose of the motion detector in an environmentally sound  
manner (electronic waste)

2.  Description

3 potentiometers 

for setting time 

(min) and bright-

ness (lux) and 

sensitivity (Meter)

Motion detector 

with sensor head

3.  Connection

 WARNING

Danger of death through electric shock!

†

†

Disconnect power source!

†

†

Cover or shield any adjacent live components.

†

†

Ensure device cannot be switched on again!

†

†

Check power supply is disconnected!

†

†

Earth and bypass! 

 

The device can be manually activated with a circuit breaker. 

After releasing the button (return of power) the device swit-
ches on (for at least 40 secs or for the time set on the device).

4.  Installation

†

†

If applicable, use optional corner bracket (9070902, 

9070903) or optional spacer frame (9070906, 9070907) for 

flexible installation as well as cable insertion from side or 

top/bottom. 

 

230V

†

†

Disconnect power source. 

Summary of Contents for theLuxa S360 WH

Page 1: ...he motion detector in an environmentally sound manner electronic waste 2 Description 3 potentiometers for setting time min and bright ness lux and sensitivity Meter Motion detector with sensor head 3 Connection WARNING Danger of death through electric shock Disconnect power source Cover or shield any adjacent live components Ensure device cannot be switched on again Check power supply is disconnec...

Page 2: ...ors at objects with highly reflec tive surfaces such as mirrors etc Do not install motion detectors near heat sources such as heating outlets air conditioning systems lamps etc Do not direct the motion detector at objects that turn in the wind such as curtains large plants etc Take account of motion direction during test run 10 20 30 40 40 10 20 30 40 40 10 20 30 40 40 5 m 1 6 m 360 Recommended in...

Page 3: ... Lux 500 Lux 7 Lux 100 Lux 10 Lux 15 Lux 50 Lux 15 Lux or want a specific brightness value to be learned using the teach in function At the desired brightness set the potentiometer to The value will be learned after 15 s Leave potentiometer at position Set time min If the motion detector detects no further movement it swit ches off after the set time If you want to change the preset time 2 min def...

Page 4: ...0 3 Min switching capacity 10 mA Switching contact μ Contact 230 V AC LED lamps 2 W 25 W LED lamps 2 W 8 W 90 W LED lamps 8 W 100 W Incandescent and halogen lamp load 2300 W Low voltage halogen lamps 2300 VA Fluorescent lamps low loss series devices uncorrected 400 VA Series corrected 400 VA Parallel corrected 400 VA 42 μF Fluorescent lamps electronic ballast 600 W Compact fluorescent tubes electr...

Reviews: