41
6. Technical data
Operating voltage:
230 V AC, +10% / –15% (1720130)
110 – 230 V AC (1720330)
Frequency:
50–60 Hz
Standby:
< 0.4 W (1720130)
0.8 W (1720330)
Max. switching capacity:
16 A (at 250 V AC, cos
ϕ
= 1)
Switching capacity:
10 A (at 250 V AC, cos
ϕ
= 0.6)
Min. switching capacity:
10 mA/230 V AC
100 mA/24 V AC/DC
Switch output:
Switching of any phase is permitted
Shortest switching time:
1 min
Switching accuracy:
to the second
Protection rating:
IP 20 in accordance with EN 60529
Protection class:
II in accordance with EN 60730-1 sub-
ject to designated installation
Software:
Class A
Operating temperature:
–30 °C … +55 °C (1720130)
–25 °C … +55 °C (1720330)
Power reserve:
10 years at +20 °C (without Bluetooth
OBELISK top3)
Time accuracy (typical):
± 0.25 s/day (25 °C)
Rated impulse voltage:
4 kV
Pollution degree:
2
Contact:
Changeover contact
Max. switching cycles with 16 A
resistive load:
50 000
Incandescent lamp load:
2600 W
Halogen lamp load:
2600 W
Fluorescent lamps (LLB low-loss
ballasts):
uncompensated
series compensated
parallel compensated
2600 VA
2600 VA
1300 VA (130 µF)