24
Electronic feed-back
The clock thermostat is set in the factory to usual heating systems in practical operati-
on. If, as a consequence of the heating system, an adjustment is necessary, select the re-
commended setting on the potentiometer (rotary knob)
4.
Pos 3:
for circulation pump/ rapid mixing valve
Pos 4:
for gasheating/storage heating/magnetic valve
Pos 2:
for slow mixing valve
Pos 1:
for floor heating/ bi-metal mixer/ oil furnance
4
8
Adjustment of the operating point
The clock thermostat is adjusted in the factory. If re-setting is necessary
due to the place of installation e.g. a cold cement wall, the measured
temperature deviation can be corrected with the pentiometer
8.
Example: Controlled temperature too high
->
Turn the potentiometer (rotary switch) in anti-clockwise direction,
see illustration.
After the roomtemperature is stabilized, repeat if necessary.
Only for Qualified Electrician