2
Connection/installation of light sensor
!
Take length of connection cable into account: max. 100 m
(2 x 1.5 mm
2
), max. 50 m (2 x 0.75 mm
2
)
!
Avoid running sensor wiring parallel to mains power
cables
¾
Ensure correct polarity. Connect power source
Mounting light sensor 9070415
¾
Mounting light sensor: 0.5-2.5 mm
2
, strip cable by 9 mm
(max. 10 mm)
max. o 4 m m
Installing light sensor 9070456
¾
Installing light sensor: 0.25-1.5 mm
2
, strip cable by 8 mm
(max. 9 mm)
<9 mm
ca. 63 mm
max. 10 mm
8–9 mm
ø
5–10 mm
<9 mm
ca. 63 mm
max. 10 mm
8–9 mm
ø
5–10 mm
IP 66
IP 40
<9 mm
ca. 63 mm
max. 10 mm
8–9 mm
ø
5–10 mm
Ø 20 mm
Ø 20 mm
4. Device description
Display & buttons
MENU
OK
OK
MENU
0
6
12
18
24
MESSWERT
LX
18
– Activate display
– Open menu
– Cancel menu
– ESC
(leave menu)
– Save
selection
– Confirm
selection
¾
Options
are displayed
Text line
Channel status
C1, C2
ON = On
OFF = Off
Lux value display
Sunrise/sunset
display
Display of the active buttons with
the relevant function
Operating instructions
YES
Confirmation
Press
OK
NO
Modify/
Change
Press
u
1. Read text line
text/symbol represents
query
2. Make a decision
MEASURED VALUE