Connecting the cable

Wiring diagrams LUNA 111 top2 / LUNA 112 top2

C1

1 2 3

N

L

L

L N

– +

Ext1

max.

 100 m

Data

Lux

max.

 100 m

 

C2

C1

1 2 3

4 5 6

N

L

L

L N

Ext1

max.

 100 m

max.

 100 m

Ext2

Data

– +

Lux

max.

 100 m

¾

†

Strip cable to 8 mm (max. 9)

¾

†

Insert cable in the open DuoFix® plug-in terminal at 45°

 

L

2 cables per terminal position possible

¾

†

To open the DuoFix® plug-in terminal, press screwdriver 
downwards

Disconnecting the cable

¾

†

Use the screwdriver to push the load line connection 
opener downwards

Summary of Contents for LUNA 111 top2

Page 1: ...307038 Digital twilight switch EN 1 Basic safety information 4 2 Proper use 4 Disposal 4 3 Installation and connection5 Mounting the time switch 5 Connecting the cable 7 Disconnecting the cable 7 Conn...

Page 2: ...12 Initial operation 12 5 Settings and functions 13 Set lux values 13 Set delay 14 Allocate sensors 15 Activating PIN code 15 Setting manual or permanent switching 16 Set external input 17 Hour counte...

Page 3: ...3 6 Technical data 21 7 Contact 22...

Page 4: ...15 OBELISK top2 memory card Avoid mechanical overload and contamination during storage transportation 2 Proper use The digital twilight switch is used for lighting equipment streets external stairways...

Page 5: ...5 3 Installation and connection Mounting the time switch Danger of death through electric shock or fire Installation should only be carried out by a qualiied electrician WARNING click...

Page 6: ...LISK top2 memory card 9070404 Test tap Load line connection Mount on DIN top hat rails as deined in EN 60715 Switched voltage free Ensure device cannot be switched on Check absence of voltage Earth an...

Page 7: ...N L L L N Ext1 max 100 m max 100 m Ext2 Data Lux max 100 m Strip cable to 8 mm max 9 Insert cable in the open DuoFix plug in terminal at 45 L2 cables per terminal position possible To open the DuoFix...

Page 8: ...0 75 mm2 Avoid running sensor wiring parallel to mains power cables Ensure correct polarity Connect power source Mounting light sensor 907 0 415 Mounting light sensor 0 5 2 5 mm2 strip cable by 10 mm...

Page 9: ...9 8 9 mm max 10mm 5 10 mm 9 mm 20 mm ca 63mm IP 66 IP 40...

Page 10: ...messwert lx 18 Activate display Open menu Cancel menu ESC leave menu Save selection Confirm selection Options are displayed Text line Channel status C1 C2 ON On OFF Off Lux value display Sunrise suns...

Page 11: ...11 Operating instructions YES Confirmation Press OK NO Modify Change Press t u 1 Read text line text symbol represents query 2 Make a decision...

Page 12: ...S PERM ON PERM OFF OVERRI ON TIMER OPERATING HOUR EXT INPUT LCD ILLUMINATION LANGUAGE PIN FACTORY SETTINGS INFO END END CHANNEL C1 LUX VALUES DELAY TIME END Initial operation DEUTSCH ENGLISH ESPANOL F...

Page 13: ...s operation 5 Settings and functions Set lux values LIGHT CHANNEL C1 LUX VALUES LUX ON LUX OFF DELAY TIME END MENU u LThe device has been preset at 15 lx for the switch on switch off level Press MENU...

Page 14: ...MINUTE MINUTE SECONDS SECONDS END MENU u u u LAn on off delay of 1 minute is preset to avoid faulty ope ration caused by lightning car headlights etc When the delay ends the channel status will lash O...

Page 15: ...DEACTIVATE u u u u u u red LED lashes on the sensor Press MENU see ig Connection options 1 LUNA max 4 light sensors 10 LUNA 1 light sensors max 16 devices LUNA light sensors LPresetting all connected...

Page 16: ...t switching Manual or permanent switching can be set via the menu in MANUAL or in the automatic screen by button combination see picture Manual control Reversing the channel status to the next automat...

Page 17: ...ultaneously Set external input For the channel an EXTERNAL INPUT see igure can be set with different functions 3 sub menus can be selected Inactive push button function switch function NOT ACTIVE The...

Page 18: ...airwells Press MENU with u select EXT INPUT and follow the indi cations on the display Hour counter The operating hours of the channel relay are displayed and deleted in the OPTIONS menu If the number...

Page 19: ...e device via the memory card Insert memory card in the twilight switch Read in out saved switching times and device setups in the time switch or start Obelisk program Remove memory card after copying...

Page 20: ...switch to the memory card Starting OBELISK program Takes on the switching times and the threshold values that are programmed on the memory card As soon as the memory card is removed the switching time...

Page 21: ...1 Fluorescent lamp switching capacity 10 AX Switching capacity min 10 mA 250 V AC 100 mA 12 V AC DC Glow lamp load 2600 W Halogen lamp load 2600 W Fluorescent lamps KVG uncorrected series corrected p...

Page 22: ...llation light sensor IP 20 IP 55 IP 66 frontside IP 40 backside 7 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Tel 49 7474 692 0 Fax 49 7474 692 150 Hotline Tel 49 7474 692 369 hotline t...

Reviews: