8.0 Technical data
The device is appropriate for use under the conditions of usual contamination. Also
observe any technical information on the device ´s nameplate deviating from this!
Subject to terminal improvements. The devices meet the requirements of the Euro-
pean Directives 73/23/EWG (Low-voltage Directive) and 89/336/EWG (Directive).
Ensure when using these devices togehter with other devices in one system that
there is no radio interference caused by the whole system.
6.0 Manual operation
7.0 Commissioning
Manual operation of HMG 8
• After a channel button is pressed, its relay is switched on for 2 actuation cycles
(two PWM periods). With the parameter setting "Actuator behavior: no heating
after switch on" the relay is switched off so that the valve is opened. Pressing
the channel button once again ends the manual mode.
• Pressing the position button at the same time as a channel button displays the
status of the channel (controlled value - output value) on the LEDs for channels
H1 to H4 as a % value in the following steps: 0 %, >0 %, >25 %, >50 %, >75 %.
HMG 8
HME 8, HMX 4 RME 8/ RMX 4
FME 8
Operating voltage
230 V/240 V ±10 %
Rated frequency
50 Hz
Power consumption
approx. 4 VA
EIB current cons.
8 mA
----
----
----
Contact-making mat.
AgSnO
Contact type
potential-free make contact element
----
Switching capacity
cos = 1 2 A (250 V~) 2 A (250 V~) 10 A (250 V~)
----
cos = 0,6
---- ---- 6 A (250 V~)
----
Incandescent lamp cap.
----
----
1400 W
----
Halogen lamp cap.
----
----
1400 W
----
Terminal dimensions
heavy duty, 0.5 mm
2
(0.8 diameter) to 4 mm
2
(cross section)
flexible lead with ferrule, 0.5 mm
2
bis 2.5 mm
2
Permissible ambient
temperature
-5 °C ... +45 °C (-5T45)
Protection class
Il following proper installation
Protection type
IP 20 meeting EN 60529
Device standard
EN 60730
Appliance
45 x 105 x 60 mm (6 TE) + (HME 4, RMX 4 3TE)
Window contact
----
----
----
20 V/ 2mA
load
typical
----
----
----
max. cable
length: 200 m
Refer to the handbook for more detailed switching capacity information for other
types of lighting
Basic device HMG 8
1
a common power supply for
thermal actuators
2
Output status display for each
channel (% value)
3 Power LED
(blinks, if no bus communication
or programmed expansion device,
refer to handbook
4
Summer mode
ON/OFF
5 Position button
(see also section 6.0)
6 Bus connection
7
Current relay status
ON/OFF
(blinks during manual, forced or
emergency operation)
8
Channel button
9 Set Phys Adr
programming key
and LED for physical address
Expansion modules HME 8, HMX 4
10 Interface
between expansion
module and the basic device
11 LED
ON = contact
(like basic device)
12 Keys
(like basic device)
5.0 Description
The ETS-database can be found
www.theben.de/downloadseite.htm#g
.
Please refer to the handbook for more detailed description of these functions (e.g.
lights, priority sequence, etc.).
<–
6
5
8
9
7
3
4
2
L N
1
10
11
12
L
N
13 14
10
L
N
11
12
L
N
11
L
N
15
Window contact module FME 8
13
COM = output voltage (all COM
ports are internally linked)
14
Inputs
15
LED status displays
If you use the window contact module
FME 8
with
JMG 4 DC
, see operating
instructions for
JMG 4 DC.
10
12
Expansion modules RME 8, RMX 4
10 Interface
between expansion
module and the basic device
11 LED
ON = contact
(like basic device)
12 Keys
(like basic device)
11
12
L
N
Theben AG
Hohenbergstr. 32
72401 Haigerloch
Tel. +49 (0) 74 74/6 92-0
Fax +49 (0) 74 74/6 92-150
Service
Tel. +49 (0) 90 01 84 32 36
Fax +49 (0) 74 74/6 92-207
[email protected]
Adresses, telephone numbers etc. at
www.theben.de