Special voltage TR top2 24 V
The devices are designed for switching mains and low voltage (SELV, PELV, FELV).
TR 612 top2 24 V, TR 622 top2 24 V, TR 641 top2 RC 24 V, TR 642 top2 RC 24 V
With these devices the type of low voltage must correspond to low voltage type of the supply
voltage (SELV = SELV, PELV = PELV, FELV = FELV)
.
If the switch output is 230 V, the time switch can be operated using low function voltage but not SELV as
supply voltage.
Lay the control cable separately from the load power.
TR 610 top2 24 V, TR 611 top2 24 V, TR 611 top2 RC 24 V
The devices are approved for switching SELV and mains voltage.
The external outputs are designed for operating voltage of 12-24 V AC and DC and not for 230 V.
310 357
~
~
~
2,5mm
2
50-60Hz
R 8a - 30T
C1/C2
16(2)A 250V~
8mm
12-24V UC
~
Data
MENU
OK
1
2
0
6
12
18
24
TR
642
top2
RC
Ext1
Ext2
~+
C1
C2
~
2,5mm
2
0,5mm -
2
8mm
12-24V UC
50-60Hz
R 10a - 30T
16(2)A 250V~
1
C1
2
3
MENU
OK
0
6
12
18
24
TR
610
top2
~+
~
+
~
+
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a - 30T
C1/C2
16(2)A 250V~
8m
m
1
C1
2
3
1
C1
2
3
Ext 2
Ext 1
4
C2
5
6
4
C2
5
6
MENU
OK
1
2
0
6
12
18
24
TR
622
top2
~+
~+
C1
C2
12 - 24 V
12 - 24 V
12 - 24 V
C2
C1
~
~
~
2,5mm
2
50-60Hz
R 8a - 30T
C1/C2
16(2)A 250V~
8mm
12-24V UC
~
Data
MENU
OK
1
2
0
6
12
18
24
TR
642
top2
RC
Ext1
Ext2
~+
C1
C2
~
2,5mm
2
0,5mm -
2
8mm
12-24V UC
50-60Hz
R 10a - 30T
16(2)A 250V~
1
C1
2
3
MENU
OK
0
6
12
18
24
TR
610
top2
~+
~
+
~
+
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a - 30T
C1/C2
16(2)A 250V~
8m
m
1
C1
2
3
1
C1
2
3
Ext 2
Ext 1
4
C2
5
6
4
C2
5
6
MENU
OK
1
2
0
6
12
18
24
TR
622
top2
~+
~+
C1
C2
12 - 24 V
12 - 24 V
12 - 24 V
C2
C1
~
~
~
2,5mm
2
50-60Hz
R 8a - 30T
C1/C2
16(2)A 250V~
8mm
12-24V UC
~
Data
MENU
OK
1
2
0
6
12
18
24
TR
642
top2
RC
Ext1
Ext2
~+
C1
C2
~
2,5mm
2
0,5mm -
2
8mm
12-24V UC
50-60Hz
R 10a - 30T
16(2)A 250V~
1
C1
2
3
MENU
OK
0
6
12
18
24
TR
610
top2
~+
~
+
~
+
~
+
12-24V UC
~
~
2,5mm
2
0,5mm -
2
50-60Hz
R 10a - 30T
C1/C2
16(2)A 250V~
8m
m
1
C1
2
3
1
C1
2
3
Ext 2
Ext 1
4
C2
5
6
4
C2
5
6
MENU
OK
1
2
0
6
12
18
24
TR
622
top2
~+
~+
C1
C2
12 - 24 V
12 - 24 V
12 - 24 V
C2
C1
TR 610 top2 24 V
TR 622 top2 24 V
TR 642 top2 RC 24 V
Electrical connection
GB
Permissible operating voltage:
12 V–24 V / 50–60 Hz +10 % –15 %, 12 V–24 V DC +10 % –15 %
Switching capacity:
16 A, 250 V~ cos
ϕ
= 1; 2 A, 250 V~ cos
ϕ
= 0.6
Incandescent lamp load, halogen load:
1400 W at 230 V or 6 A
Flashlight (EB) 230 V:
180 W
Compact lamp (EB) 230 V:
7 x 7 W, 6 x 11 W, 5 x 15 W, 5 x 20 W, 4 x 23 W
Fluorescent lamps, parallel-corrected 230 V:
1 x 58 W / 7 µF, 2 x 36 W (4.5 µF each), max. 12 µF
Halogen metal halide lamps 230 V:
1 x 70 W (12 µF)
Standby output min.
Power consumption typ.
0.3 W
1.0 W
(TR 612 top2 24 V, TR 622 top2 24 V)
0.3 W
0.7 W
(TR 610 top2 24 V, TR 611 top2 24 V)
0.9 W
1.3 W
(TR 611 top2 RC 24 V)
1.5 W
2.5 W
(TR 642 top2 RC 24 V)
1.5 W
2.0 W
(TR 641 top2 RC 24 V)
Mode of operation:
Type 1 BSTU in accordance with EN 60730-1
Pollution degree:
2
Rated impulse voltage:
4 kV
Protection class:
II for supply with FELV and/or mains switching
III for supply with SELV and switching of SELV
Protection rating:
IP 20 in accordance with EN 60529
Power reserve:
8 years at 20 °C ℃
610 4 100
611 4 100
611 4 300
612 4 100
622 4 100
641 4 300
642 4 300
Technical data
The technical data and the section on the "electrical connection" of 230 V devices
(see operating instructions) do
not
apply to devices with special voltage.
External outputs
Serviceadresse
Theben AG
Hohenbergstr. 32
72401 Haigerloch
DEUTSCHLAND
Fon +49 (0) 74 74/6 92-0
Fax +49 (0) 74 74/6 92-150
Hotline
Fon +49 (0) 74 74/6 92-369
Fax +49 (0) 74 74/6 92-207
[email protected]
Addresses, telephone numbers etc.
www.theben.de