background image

8

L

The 

extended function duration

 does not work if the time 

delay A is set to 

pulse

 or the staircase light function is 

activated.

Activating a function

†

Press button for 3 s and release ▻ the LED fl ashes 2 x; 

lighting is switched on for the set time

†

Press button for > 6 s and release ▻ the LED fl ashes 3 x; 

lighting is switched off for the set time

Leaving a function

†

Briefl y press button once

Acoustic sensor sensitivity 

An integrated microphone complements motion detection 

and enables use even in rooms with alcoves. The function 

is activated as soon as the light (channel A) is switched on. 

Each time an acoustic signal is detected the channel A time 

delay is restarted. If the light goes out, the microphone is only 

activated briefl y.

L

If the set brightness target value A is exceeded, the micro-
phone is switched off.

Level

Sensitivity

Off

Deactivated (default)

1

Insensitive

2

Standard 

3

Sensitive

LED display motion 

Motion detection is indicated by the LED.

2. Control commands

Teach-in channel A

The detector saves the current surrounding brightness as the 

new switch-on brightness.

theSenda B/app

theSenda P

Switching light (on/off)

theSenda B/app

theSenda B

Summary of Contents for 2060650

Page 1: ...es ponding theSenda Plug app iOS Android theSenda B app for short bezel frames adapted for different switch ranges can be ordered optionally theMura S180 100 bezel frames adapted for different switch ranges can be ordered optionally see www theben de theMura 2 Safety Assembly and installation should only be carried out by a qualified electrician somebody who has completed appropriate professional ...

Page 2: ...A 1 3 6 6 plus 8 max 6 detectors with ELPA 041 047 LThe time delay is set at the staircase light timer switch Do not connect the lighting directly to the detector The 4 conductor switching must be used for the stair case light timer switch L N Master L L Master L L N L 4 3 e g ELPA 2 x theMura S180 100 2W UP onlyTheben devices max 12 pieces 5 Installation LFor installation in device housing concea...

Page 3: ...he potentiometer to the desired time 10 s 1 min 5 min 10 min 30 min If you wish to use the pulse function e g for a staircase light timer switch Set the potentiometer to As long as motion is detected the contact closes every 10 s for 0 5 s LAt the 2 wire motion detector theMura S180 100 2W no time delay can be set The time delay set on the staircase lighting timer switch applies The time delay of ...

Page 4: ... min theMura S180 101 When the button is pressed briefly the light switches on for a certain time depending on the duration of motion and the set time delay LWith theMura S180 101 the surrounding brightness is checked after 30 min If there is sufficient brightness the light is switched off despite the presence of persons Switching off manually 2 min 30 s 30 s 30 s 2 s 2 s t t t Normalbetrieb Norma...

Page 5: ...te control Open the theSenda Plug app Press the Bluetooth symbol in the app on the top left hand side Briefly press the Bluetooth button on theSenda B LED flashes red devices are searched for Confirm with OK LED lights up red 9 Parameters and control commands via app 1 Parameters Brightness setpoint value A theSenda B app theSenda P Brightness actual value A Check of the current measured actual br...

Page 6: ...vity The detector has 3 sensitivity levels Level Sensitivity 1 Very insensitive 2 Insensitive 3 Standard default theSenda B app theSenda P Time delay A theSenda B app theSenda P Short presence A If a room is only occupied briefly the channel A time delay is ended early 2 min provided that the set time delay is 2 min Channel function H Channel H presence isolated contact e g to control a fan in the...

Page 7: ...n it can be switched on manually but not switched off The light will not be switched off again until after the set time delay Orientation light time delay The integrated orientation light conveys a sense of security and good orientation in dark rooms and corridors Time delay When the channel A time delay has expired the orientation light comes on for the set time delay On The orientation light alw...

Page 8: ...enables use even in rooms with alcoves The function is activated as soon as the light channel A is switched on Each time an acoustic signal is detected the channel A time delay is restarted If the light goes out the microphone is only activated briefly LIf the set brightness target value A is exceeded the micro phone is switched off Level Sensitivity Off Deactivated default 1 Insensitive 2 Standar...

Page 9: ... Acoustic sensor sensitivity Off LED display motion Off Switch on behaviour Start up phase 45 s after restoration of power The red LED flashes at one second intervals all switch contacts are closed The detector does not respond to push button com mands and remote control commands When no one is present all contacts open after 45 s Operation The detector is ready for operation LED off LED display L...

Page 10: ...ad Compact fluorescent lamps LED lamps 2060650 2060653 2060750 2060655 2060755 2300 W 2060650 2060653 2060750 2060655 2060755 1150 VA 2060650 2060653 2060750 2060655 2060755 2 W type 40 W 2 W type 450 W 2060660 2060760 2060670 2060770 Switching capacity H 50 W 50 VA max 2 A 2060655 2060755 Contact type H µ contact Protection rating IP 20 in accordance with EN 60529 Protection class II in accordanc...

Page 11: ...11 13 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de Addresses telephone numbers etc www theben de ...

Reviews: