MAKING ELECTRICAL CONNECTIONS

Connecting Power

There are four options for Power input into the batten. 

19 Pin Male Circular Connector (Socapex) 

– This connector comes pre-wired ready to connect to a 

female connector

SO Cable 

– The number of circuits determines the number of conductors, either 12/3, 12/4, or 12/5. 

The length of cable extending beyond the batten is fixed at the factory according to approved 

drawings. A connector is not supplied, so choose a connector that will meet code requirements in your 

area.

Terminal Box

– The batten will have a terminal with a terminal strip for connection of  wires.

Extended Internal Conductors

– The end of the batten has a ¾” NPT threaded socket for electrical 

fittings. The conductors will need to be enclosed in conduit provided by others. Each power circuit 

will have a hot and neutral conductor (up to six circuits), and there will be one ground that is shared by 

all circuits. Connection to building power should be done by a licensed electrician. See the color code 

chart for circuit conductor colors.

SO Cable 

Extended Internal conductors

Terminal Box 

ELECTRICAL CONNECTIONS MAY ONLY BE MADE BY INDIVIDUALS 

FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THIS 

PRODUCT AND THE HAZARDS INVOLVED.

19 Pin Connector

Maintenance

The M

EGA

B

ATTEN

requires very little maintenance once installed. The M

EGA

B

ATTEN

has a powder coat 

finish so it can be wiped down with a damp cloth to remove accumulated dust. In the event of a damaged 

outlet, turn off power to the M

EGA

B

ATTEN

. A replacement can be ordered and repaired on site by a 

qualified individual.