background image

 

z

 

DO NOT FORCE THE TOOL     

It will do a better and safer job at its designed rate. Never try to 
split logs larger than those indicated in the specifications table. 
This could be dangerous and may damage the machine. 
Do not use log splitter for a purpose for which it was not 
intended.

 

 

z

 

NEVER LEAVE THE TOOL RUNNING UNATTENDED     

Do not leave the tool until it has come to a complete stop.

 

 

z

 

DISCONNECT POWER 

Unplug when not in use, before making adjustments, changing 
parts, cleaning, or working on the log splitter. Consult the 
technical manual before servicing.

 

 

z

 

PROTECT THE ENVIRONMENT 

Take used oil to an authorized collection point or follow the local 
stipulations that apply where the log splitter is being used.   
Do not discharge into drains, soil or water.

 

 

z

 

MAINTAIN YOUR LOG SPLITTER WITH CARE 

Keep the log splitter clean for the best and safest performance.

 

 

z

 

STORE THE LOGSPLITTER SAFELY 

Store the log splitter away from children and others not qualified 
to use it.

 

 

 

 

TABLE OF CONTENTS   

Safety Warnings & Cautions ………………………………………………………………….…. 2 
Working Conditions ….……………………………………………………………………….……4 
Specifications ……………………………………………………………………………………... 5     
Electrical Requirements ………………………………………………………………………….. 5 
Set up and Preparation for Operation ………………………………………………………….. 6 
Wiring Diagram …………………………………………………….……………………………... 7 
Hydraulics Diagram ..……………………………………………………………………………... 7 
Log Splitter Operation ……………………………………………………………………………. 8 
Freeing a Jammed Log …………………………………………………………………………. ..9 
Ram Adjustment…………………………………………………………………………………..10 
Replacing The Hydraulic Oil ……………………………………………………………………. 11 
Sharpening The Wedge ………………………………………………………………………… 11 
Trouble Shooting ………………………………………………………………………………... 12 
Parts Schematic……………………………………………………………………………….…. 13 
 

WORKING CONDITIONS 

This log splitter is a domestic use model. It is designed for operating under ambient 
temperatures b5

o

C and 40

o

C and for installation at altitudes no more than 1000m 

above M.S.L. The surrounding humidity should be less than 50% at 40

o

C. It can be stored 

or transported under ambient temperatures between -25

o

C and 55

o

C. 

 

4

Summary of Contents for THLS-4

Page 1: ...handy co uk Before use please read understand this manual paying particular attention to the safety instructions Whilst every effort is made to accurately represent the product small variations in colour design and specification may occur We reserve the right to alter the product without giving notice 23 06 2014 ...

Page 2: ...nts or flammable liquids pose a potential hazard z INSPECT YOUR LOG SPLITTER Check your log splitter before turning it on Keep guards in place and in working order Frequently check to see that keys and adjusting wrenches are removed from the tool area before turning it on Replace damaged missing or failed parts before using it z DRESS PROPERLY Do not wear loose clothing neckties or jewelry rings w...

Page 3: ...splitter z KEEP VISITORS AND CHILDREN AWAY The log splitter must only be operated by one person Other people should keep a safe distance from the work area especially when the log splitter is under operation Never use another person to help you with freeing a jammed log z INSPECT YOUR LOG Make sure there are no nails or foreign objects in logs to be split The ends of the logs must be cut square Br...

Page 4: ... drains soil or water z MAINTAIN YOUR LOG SPLITTER WITH CARE Keep the log splitter clean for the best and safest performance z STORE THE LOGSPLITTER SAFELY Store the log splitter away from children and others not qualified to use it TABLE OF CONTENTS Safety Warnings Cautions 2 Working Conditions 4 Specifications 5 Electrical Requirements 5 Set up and Preparation for Operation 6 Wiring Diagram 7 Hy...

Page 5: ...10mm Stroke Length 220mm 370mm Weight 38kg 45kg The diameter of the log is not the only factor that determines how easy it will be to split A small log can be difficult to split when it has knots or is a particularly hard wood ELECTRICAL REQUIREMENTS Connect the main leads to a standard 230V 10 50Hz 1Hz electrical supply which has protection devices for under voltage over voltage over current as w...

Page 6: ...ances ONLY 11 Hydraulic Control Lever 12 Control Lever Guard 13 Bleed Screw 14 Oil Drain Bolt w Dipstick Before operating the log splitter the Bleed Screw should be loosened a few rotations until air can go in and out of the oil tank smoothly Air flow through the Bleed Screw hole should be noticeable while the log splitter is working Before moving the log splitter make sure the Bleed Screw is tigh...

Page 7: ...s sealed with glue to ensure the log splitter works under pressure no more than is listed in the specifications The setting was made by a qualified mechanic with professional instruments Unauthorized resetting will reduce the performance of the hydraulic pump to or RESULT IN SERIOUS INJURY AS WELL AS DAMAGE TO THE MACHINE WIRING DIAGRAM PLUMBING DIAGRAM 7 ...

Page 8: ...lic Control Lever activation To operate the Hydraulic Control Lever draw the Trigger backward with your index finger before pushing the Hydraulic Control Lever forward Never force the log splitter for more than 5 seconds Do not keep pressure on it to split excessively hard wood After 5 seconds of constant use the oil under pressure will be overheated and the machine could be damaged For such extre...

Page 9: ...mage the machine Do not attempt to split 2 pieces of logs at the same time One of them may be thrown by the machine which could cause serious injuries to the user FREEING A JAMMED LOG z Release both controls z After the log pusher moves back and completely stops at its starting position insert a wedge of wood under the jammed log z Start the log splitter to push the wedge wood to go completely und...

Page 10: ... knob along the pipe to set the gap size The closer you move the Ram Adjustment Knob towards the Log Splitter and the more you slide it down the pipe the smaller the gap will be left between the ram and the splitting wedge o If the gap is correct you should place the hand knob against the log splitter o If the gap is too small you can leave an equivalent space between the knob and the logsplitter ...

Page 11: ... back into the oil tank while keeping the log splitter held upright z Make sure the level of the refilled oil is just between the 2 grooves around the Dipstick z Clean the Oil Drain Bolt before replacing it Make sure they are tightened to avoid leaks before lowering the log splitter back to a horizontal position Periodically check the oil level to ensure it is between the 2 grooves around the Dips...

Page 12: ...ure Limiting Screw Lower max pressure rating was set Contact the dealer The log pusher moves jerkily making unfamiliar noises or vibrating excessively Lack of hydraulic oil Excessive air in the hydraulic system Check oil level for possible oil refilling Remove the bleed screw Operate the ram 5 or 6 times without a log in place Return the bleed screw and split the log If the problem continues conta...

Page 13: ...PARTS SCHEMATIC 13 ...

Page 14: ... TH155 78 Fan 1 26 TH114 14 O ring 1 79 TH155 79 Block Turn 1 27 TH114 13 Bleed Screw 1 80 TH155 80 Shroud 1 28 TH114 62 Washer Groupware 1 81 TH155 81 Flat Washer 2 29 TH186 63 Dipstick 1 82 TH155 82 Spring Washer 3 30 TH186 6 Piston Rod 1 83 TH155 83 Screw 2 31 TH114 9 Lift Handle 1 84 TH114 59 Support Leg 1 32 TH114 10 Screw 2 85 TH155 85 Nut 5 33 TH186 20 Frame Tube 1 86 TH114 60 Bolt 5 34 TH1...

Page 15: ... TH155 78 Fan 1 26 TH114 14 O Ring 1 79 TH155 79 Block Turn 1 27 TH114 13 Bleed Screw 1 80 TH155 80 Shroud 1 28 TH114 62 Washer Groupware 1 81 TH155 81 Flat Washer 2 29 TH114 63 Dipstick 1 82 TH155 82 Spring Washer 3 30 TH114 6 Piston Rod 1 83 TH155 83 Screw 2 31 TH114 9 Lift Handle 1 84 TH114 59 Support Leg 1 32 TH114 10 Screw 2 85 TH155 85 Nut 5 33 TH114 20 Frame Tube 1 86 TH114 60 Bolt 5 34 TH1...

Page 16: ... procedure followed was in according with Annex I of the Directive 2006 42 EC Name of the Notified Body TÜV Rheinland LGA Products GmbH Address Tillystrasse 2 90431 Nurnberg GERMANY Standards and technical specifications referred to 06 42 EC Annex I 05 06 EN 60204 1 2006 A1 EN 609 1 1999 A2 Authorised signatory and technical file holder Date 1 7 2012 Signature Name title Mr Simon Belcher Managing ...

Page 17: ... procedure followed was in according with Annex I of the Directive 2006 42 EC Name of the Notified Body TÜV Rheinland LGA Products GmbH Address Tillystrasse 2 90431 Nurnberg GERMANY Standards and technical specifications referred to 06 42 EC Annex I 05 06 EN 60204 1 2006 A1 EN 609 1 1999 A2 Authorised signatory and technical file holder Date 1 7 2012 Signature Name title Mr Simon Belcher Managing ...

Page 18: ...arantee period please contact Customer Service on 01793 333212 or email customerservice handydistribution co uk If the issue cannot be resolved over the telephone or by email you may be referred to your local approved service dealer Please keep your sales receipt as proof of purchase Your statutory rights remain unaffected Guarantor Handy Distribution SN3 4NS Whilst every effort is made to accurat...

Page 19: ...TTERS PETROL BRUSHCUTTERS PETROL MULTICUTTERS PETROL MULTICUTTERS ELECTRIC PETROL CHAINSAWS ELECTRIC PETROL CHAINSAWS LOG SAW HORSES LOG SAW HORSES CORDLESS PETROL CORDLESS PETROL HEDGETRIMMERS HEDGETRIMMERS ELECTRIC PETROL TILLERS ELECTRIC PETROL TILLERS AERATORS DETHATCHERS AERATORS DETHATCHERS GARDEN SALT SPREADERS GARDEN SALT SPREADERS PUSH TOWED ROLLERS PUSH TOWED ROLLERS SNOW CLEARANCE TOOLS...

Page 20: ...To order spare parts and see the complete range of garden machinery and garden equipment from Handy visit www thehandy co uk Spares Support 01793 333212 ...