background image

 

 

 

 

2. Description 

 

Figure 2-1. Appearance of TFortis SG-Cam 
 
SG-Cam    device  has  a  metal  enclosure  protected from dust  and  moisture 
according to IP67 . The device has a cable gland with a rubber sleeve for 
three cables: 

  Ethernet cable from the switch, 

  Ethernet cable of the video camera 

  grounding cable. 

 
There is enough space inside SG-Cam to accommodate the excess cable 
coming from the video camera (Figure 2-2). 
 
Application  of  a  single  large  cable  gland  with  a  dedicated  rubber  sleeve 
allows  the  RJ45  socket  of  the  camera  to  be  inserted  into  the  lightning 
protection  device  without  cutting  off  the  camera  socket,  thus  retaining  the 
warranty of the camera manufacturer. Instruction for connection is available 
in the Installation section of this document.  
 

Summary of Contents for SG-Cam

Page 1: ...1 Operating Manual SG Cam Surge protection unit for video cameras Version 1...

Page 2: ...2 Grounding of the switch is obligatory It is recommended to check the integrity of lightning protection device at the beginning and the end of the storm season and immediately after the storm...

Page 3: ...Description 5 3 Technical parameters 7 4 Operating conditions 8 5 Installation 8 5 1 Installation on the wall or pole 8 5 2 Pulling cables through the cable gland 9 5 3 Cable connection 11 6 Supply sc...

Page 4: ...TFortis SG Switches Figure 1 Typical application scheme Features High level of protection against lightning interferences All weather performance IP67 housing Operation in a wide range of temperatures...

Page 5: ...amera grounding cable There is enough space inside SG Cam to accommodate the excess cable coming from the video camera Figure 2 2 Application of a single large cable gland with a dedicated rubber slee...

Page 6: ...6 Figure 2 2 Device interior Figure 2 3 Example of connection...

Page 7: ...C U 9V 57V Nominal current direct IL 600mA 600mA line ground 2 Nominal discharge current 8 20 In 1 kA C2 2 kV 1 kA Protection voltage level at In Up 450 V C3 Protection voltage level at 1 kV s Up 600...

Page 8: ...end of the storm season and immediately after the storm 5 Installation 5 1 Installation on the wall or pole Use M5 bolts from the supply kit to screw the brackets to the device housing Figure 5 1 Fig...

Page 9: ...rilling of the housing will lead to loss of device integrity and as a result loss of product warranty 5 2 Pulling cables through the cable gland Cut the hole in the rubber sleeve Pull the cables throu...

Page 10: ...10 Assemble the cable gland according to the Figure below Tighten the cable gland...

Page 11: ...from the video camera to RJ45 CAMERA switch If the cable from the video camera ends with a plug make an Ethernet cable of a minimum length and use it to connect the video camera Connect the grounding...

Page 12: ...12 Figure 5 3 1 Connection scheme It is recommended to use a 4 pair twisted pair at least category 5 Figure 5 3 2 Separation of the Ethernet cable 6 Supply scope...

Page 13: ...g is missing or if the serial number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or...

Reviews: