6.1 Resetting the switch to factory settings 

Before  start,  set  the  switch  to  default  settings.  To  do  this,  press  and  hold  the 
DEFAULT button until the DEFAULT indicator is ON. The default IP address of 
the switch is 192.168.0.1.  

6.2 IP address setting 

All software functions of the switch can be managed, configured and monitored 
using  the  built-in  WEB  interface  and  Telnet.  Below  is  the  description  of  WEB-
based configuration. Configuration via Telnet (see the Configuration Manual). 

The  switch  can  be  managed  from  remote  stations  at  any  point  of  the  network 
via  a  standard  web  browser  (for  example,  Microsoft  Internet  Explorer).  The 
browser is a universal access tool and can directly access the switch using the 
HTTP protocol. 

Connect  any  switch  port  to  an  Ethernet  network.  Note  that  if  the  device  is 
configured  over  a  network,  the  IP  address  of  the  management  workstation 
should belong to the same IP network. For example, if the default IP address of 
the  switch  is  192.168.0.1,  then  the  IP  address  of  the  workstation  should  be 
192.168.0.x  (where  x  is  a  number  from  2  to  254);  the  default  subnet  mask  is 
255.255.255.0. 

Open the web browser and enter the IP address http://192.168.0.1. 

 

Figure 6.2 Entering the IP address of the switch 

 

6.3 User name and password setting 

Until  the  "user  name"  and  "password"  are  set,  you  will  log  in  without  entering 
this data. After the password is set, you will need to authenticate when you log 
in.  

Summary of Contents for PSW-2G8F+Hot

Page 1: ...Multifunction Gigabit Managed Switch with PoE support IEEE802 3at up to 30 W per port for connecting eight IP video cameras designed to be used in hot climate PSW 2G8F Hot Operating Manual Version 1...

Page 2: ...unit under voltage SFP port operates only at 1000 Mbps Fast Ethernet SFP modules will not operate To ensure proper operation of lightning protection provide proper grounding according to the Electric...

Page 3: ...unctions 15 3 8 1 Restarting cameras in case of hanging 15 3 8 2 Cable tester 16 3 8 3 Remote camera polling 16 4 Technical specifications 17 5 Operating conditions 17 6 Preliminary setting 18 6 1 Res...

Page 4: ...s in hot climate PSW 2G8F Hot connection scheme 8 cameras 2 Features The switch is built based on industrial hardware with a wide range of operating temperatures All heat generating components of the...

Page 5: ...power supply eliminating the need for an additional power supply unit A built in lightning protection for Ethernet ports and 230 VAC power supply protects the switch and connected cameras from pulse i...

Page 6: ...distribution frame allows for optical cable splicing inside the switch and connecting it to SFP modules The automatic circuit breaker allows to de energize the switch during configuring and debugging...

Page 7: ...e air circulation between the shield and the enclosure for additional cooling of the switch The shield is attached to the enclosure at several points to eliminate heat passage from the external casing...

Page 8: ...8 Figure 3 1 3 Switch operation in hot climate 3 2 Optical distribution frame IMPORTANT Nylon ties shrinkable plastic sleeves pigtails and adapters are not included in the scope of supply...

Page 9: ...supply unit is limited The power supply unit has an aluminum radiator that is pressed against the back panel of the switch to remove the heat to the switch enclosure Figure 3 3 Power supply unit 3 4...

Page 10: ...10 Figure 3 4 1 Switch board Figure 3 4 2 Layout of components on the switch board...

Page 11: ...per configuration Table 3 4 1 Table 3 4 1 Configuration of PoE jumpers Position Power supply option 1 2 and 3 6 Option A 4 5 and 7 8 Option B As PoE standard is backward compatible with the common PoE...

Page 12: ...PoE B indicator is ON when power is supplied by free pairs pairs 4 5 and 7 8 3 4 7 LINK indicators A blinking LINK indicator shows that data are transmitted via the corresponding port 3 4 8 Power indi...

Page 13: ...or on the switch board Figure 3 5 2 Tamper sensor curtain on the power supply unit cover IMPORTANT Make sure you place the power supply unit cover correctly when closing it The shutter shall fall betw...

Page 14: ...ctromagnetic interferences The switches are resistant to powerful microsecond pulse interferences according to GOST R 51317 4 5 as per Table 3 7 1 with performance criteria B temporary disruption of p...

Page 15: ...service requests Ping Reduction of port speed below the established limit Speed The switch continuously once a minute monitors the Link signal from the IP camera If the switch fails to detect the Link...

Page 16: ...w rate goes below the established limit and fails to restore the switch decides that the camera is hanging and restarts it The user may specify the limit values see the Configuration Manual 3 8 2 Cabl...

Page 17: ...ssion distance up to 100 m Power supply voltage 230 VAC 187 to 253 V Maximum power consumption 200 W Design dimensions 459 247 175 mm maximum weight 11 kg environmental protection rating IP67 cable gl...

Page 18: ...Microsoft Internet Explorer The browser is a universal access tool and can directly access the switch using the HTTP protocol Connect any switch port to an Ethernet network Note that if the device is...

Page 19: ...l be performed with 230 VAC power off 6 5 Activation of redundancy protocols If you connect the switches into a ring then you need to enable the RSTP protocol Otherwise if there are alternative paths...

Page 20: ...he enclosure will lead to loss of the switch integrity and result in the loss of product warranty 7 2 Installation of the cabinet on lamp posts To install the cabinet on the lamp post use TFortis Atta...

Page 21: ...n ties Optical fibers are laid in a splice cassette each including 12 shrinkable plastic sleeves Welded pigtails are connected to SC adapters located on the adapter plane Then the adapters are connect...

Page 22: ...stance should not exceed 4 Ohm 7 5 Camera connection Camera connection recommendations 1 use a 4 pair shielded twisted pair at least category 5 2 use shielded RJ45 connections 3 use minimum length of...

Page 23: ...nged removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment wit...

Page 24: ...ideo surveillance systems operation and adjustment of equipment call 8 a m to 4 p m Moscow time 7 342 270 112 8 7 342 260 20 30 send an e mail to tfortis fort telecom ru All technical documentation is...