background image

16

 

 

7. 

Manufacturer’s warranty 

Warranty period for the device 

– 36 months from the sale date. The device is 

accepted for warranty maintenance and repair only in full completeness. 
Warranty repair is not performed in following cases: 

•  if warranty period has expired; 
•  if there is no label with serial number on the product housing, and also 

if serial number was changed, removed or illegible; 

•  if there are external and internal mechanical damages (chips, cracks, 

deformation, damage to the power cord, breaks and cracks of 
connectors), traces of chemicals, corrosive environments, liquids, 
heavy contamination, as well as the presence of insects or traces of 
their presence; 

•  due to non-compliance with the rules of connection and operation, as 

well as non-compliance of power specified in the operating manual; 

•  due to force majeure, third party action and other reasons that doesn’t 

depend on manufacturer. 

Summary of Contents for PSW-11

Page 1: ...1 Operation Manual PSW 11 Multifunctional Gigabit Switch for IP video surveillance systems Version 5...

Page 2: ...y units is forbidden When connecting the computer to the switch remove PoE jumpers at this port For effective operation of lightning protection is required high quality grounding according to the ELC...

Page 3: ...Restart of video cameras at their hanging 12 3 Technical parameters 12 4 Operation conditions 12 5 Presetting 13 5 1 Configuring PoE on port 13 5 2 Speed mode configuration for SFP port 13 5 3 Enablin...

Page 4: ...the second to connect the video camera Figure 1 Connection Scheme of the PSW 11 Weatherproof version The body of the device is made of a techno polymer that is resistant to Stringent Operating Conditi...

Page 5: ...e switch to the Power Supply 220V and excludes need in additional PSU Lightning protection Built in Lightning protection of Ethernet ports and 220V PSU reliably protects both the switch and connected...

Page 6: ...6 2 Description 2 1 Appearance Figure 2 1 1 PSW 11 outside view Figure 2 1 2 PSW 11 inside view...

Page 7: ...Element arrangement of PSW 11 During normal operation CPU indicator must light intermittently with a frequency of 2s 1 sec on 1 sec off PoE Jumpers LINK and PoE indicators RESTART jumper TIMER jumper...

Page 8: ...he PoE standard terminology first one is named as mode A and the second mode B Power is supplied to video cameras installed into TFortis TH camera housing using mode A and mode B simultaneously I When...

Page 9: ...igure 2 3 Power supply scheme over PoE in different cases TFortis TH camera housing Pairs 1 2 and 3 6 IEEE802 3af Pairs 4 5 and 7 8 Passive PoE Pairs 1 2 and 3 6 IEEE802 3af Pairs 4 5 and 7 8 Passive...

Page 10: ...5 standard with a degree of rigidity according to Table 2 5 1 with performance criteria B Switches are resistant to dynamic changes in the voltage of the AC electrical network in accordance with stan...

Page 11: ...tainability is preserved during fluctuations in supply voltage from 187 to 246 V 2 6 Cold start The most critical moment in the operation of the video camera is the process of its activation at low am...

Page 12: ...ontrol of IEEE 802 3x supports IEEE802 3af 15 4 W at a port supports Passive PoE 15 4 W at a port data and PoE transmission distance up to 100m Power supply unit supply voltage 220V from 187V to 246V...

Page 13: ...optical SFP module with the declared speed up to 155MGb operates only in 100M mode 5 3 Enabling Preheating of camera housings When the camera is turned on in the cold it may not start or even worse fa...

Page 14: ...he product is shown on the Fig 6 1 1 Figure 6 1 Marking of the fastening IMPORTANT Drilling of the housing leads to a violation of the sealing of the entire commutator and as a consequence the loss of...

Page 15: ...starting current appears and it exceeds the nominal value In order to avoid false alarms of the protection devices it is recommended to choose models with the characteristic C for a current of at lea...

Page 16: ...number was changed removed or illegible if there are external and internal mechanical damages chips cracks deformation damage to the power cord breaks and cracks of connectors traces of chemicals cor...