background image

 

RF205 Series   

Programmable RF room thermostat 

             

 

7. Configuration Setting

 

Enter into Configuration Setting by pressing        briefly during Power-off Status. Then press      sequentially to 

view and amend (if required) parameters noted below.   

You can confirm any changed parameters by pressing 

. Press the Power Button          to exit configuration. 

 

Display symbols 

Options Properties 

Remark 

01 

Inside  sensor  temperature 

correction 

Range: -9 to +9

   

Press ▲ or ▼ for adjustment. 

02 

Temperature differential 

Range: 1 – 5 

          Press ▲ or ▼ for adjustment. 

03 

5+2 days, 6+1 days or 7 

days programmable 

schedule selection 

A1: 5+2 days programmable   

A2: 6+1 days programmable 

A3: 7 days programmable 

Press ▲ or ▼ to select A1, A2 or A3. 

00 or AA 

Display IP address XX XX 

To  refresh  the  RF  matching.  When  power  is  connected,  press 

and hold the Recessed button in receiver for 5 seconds, the LED 

indicator  will  be  flickering  for  10  seconds.  During  the  period  of 

flicker,  select  OO  /  AA  configuration  display  (Keep  transmitter 

close to receiver), press 

  for matching. 

OO: waiting for match. AA: matched already. 

The  receiver’s  IP  code  (printed  on  the  side  of  the  receiver)  is 

shown in the lower right-hand corner of the LCD. 

RS 

Reset to factory setting 

Press 

  for 5 seconds to reset schedule 

8. Warranty 

This product has 12 months warranty from purchase date. Malfunctions due to mis-use or mis-application are 

not covered by the warranty. 

9. ErP Directive (EU regulation no. 811/2013) 

ErP Class I

 : 

Contribution to system energy efficiency: 1%   

On/off room thermostat: A room thermostat 

that controls the on/off operation of a heater.  Performance parameters are determined by  the thermostat’s 

mechanical construction.   

 