RF205 Series
Programmable RF room thermostat
7. Configuration Setting
Enter into Configuration Setting by pressing briefly during Power-off Status. Then press sequentially to
view and amend (if required) parameters noted below.
You can confirm any changed parameters by pressing
. Press the Power Button to exit configuration.
Display symbols
Options Properties
Remark
01
Inside sensor temperature
correction
Range: -9 to +9
℃
Press ▲ or ▼ for adjustment.
02
Temperature differential
Range: 1 – 5
℃
Press ▲ or ▼ for adjustment.
03
5+2 days, 6+1 days or 7
days programmable
schedule selection
A1: 5+2 days programmable
A2: 6+1 days programmable
A3: 7 days programmable
Press ▲ or ▼ to select A1, A2 or A3.
00 or AA
Display IP address XX XX
To refresh the RF matching. When power is connected, press
and hold the Recessed button in receiver for 5 seconds, the LED
indicator will be flickering for 10 seconds. During the period of
flicker, select OO / AA configuration display (Keep transmitter
close to receiver), press
for matching.
OO: waiting for match. AA: matched already.
The receiver’s IP code (printed on the side of the receiver) is
shown in the lower right-hand corner of the LCD.
RS
Reset to factory setting
Press
for 5 seconds to reset schedule
8. Warranty
This product has 12 months warranty from purchase date. Malfunctions due to mis-use or mis-application are
not covered by the warranty.
9. ErP Directive (EU regulation no. 811/2013)
ErP Class I
:
Contribution to system energy efficiency: 1%
On/off room thermostat: A room thermostat
that controls the on/off operation of a heater. Performance parameters are determined by the thermostat’s
mechanical construction.