TFA MALIBU WIRELESS POOL THERMOMETER Instruction Manual Download Page 2

 

5

Indoor relative 
humidity %

 

Indoor relative 
humidity %

 

2. 

Using the + button, set the time zone. The range runs from –
2h to +5h in consecutive 1 hour intervals. 

3. 

Confirm with the SET button and enter the “

Time reception 

ON/OFF setting

”.

 

 

TIME RECEPTION ON/OFF SETTING 

 

 
 

 

 
 

 
 
 

 

In areas where no DCF-77 time is possible, you also have the 
possibility to deactivate the DCF reception manually (OFF). The 
clock will then work as a normal quartz clock. (Default setting is ON). 
1. 

The symbol “ON” will be flashing on the LCD.  

2. 

Use the + button to deactivate (OFF) the time reception 
function. 

3. 

Confirm with the SET button and enter the “

12/24-Hour 

Display setting

”.

 

 

 

Note: 
If the time reception function is deactivated (OFF) manually, the 
clock will not attempt any reception of the radio-controlled time 
(DCF time) as long as the time reception OFF function will be  
activated (ON) again. If the time reception is deactivated (OFF) 
the DCF symbol disappears. 

 

 

12/24 HOUR TIME DISPLAY SETTING 
 
 
 

 

1. 

“24h” will be flashing. 

2. 

Press the + button to select the “12h” or “24h” display mode. 

3. 

Confirm with the SET button and to enter the “

Manual Time 

setting

”. 

 

MANUAL TIME SETTING 

 

 

 

 
 

 

In case the device is not able to attempt the radio-controlled time 
(disturbances, transmitting distance, etc.), the time can be manually 
set. The clock will then work as a normal quartz clock. 
To set the clock: 
1. 

The hour digits will be flashing on the display. 

2. 

Use the + button to adjust the hours. 

3. 

Press the SET button to go to the minute setting. 

4. 

Use the + button to adjust the minutes. Press and hold the 
button in the setting mode for fast running.  

5. 

Confirm with the SET button and enter the “º

C/ºF temperature 

unit setting

”.  

 

Note: 

By a successfully reception of the DCF signal and if the DCF 
reception is activated (ON), the manually set time will be overwritten. 
During the reception the DCF symbol will be flashing. If the reception 
is not successful received, the DCF symbol disappear. The next 
attempt will still be held.  

 

°C/°F TEMPERATURE SETTING: 

 

 
 

 

The default temperature is set to °C (degree Celsius). To select °F 
(degree Fahrenheit): 
1. 

During “ºC” will be flashing, use the + button to toggle between 
“ºC” and “ºF”. 

2. 

Once the desired temperature unit has been chosen, confirm 
with the SET button and enter the “

Factory setting

” or press 

the MAX/MIN / RESET button to exit the manual setting mode. 

 
 

FACTORY RESET (FAC)

 

 
 

 
 
 
 
 

To reset the temperature station to the factory settings: 
1. 

Press and hold the + button for about 3 seconds to reset the 
manual settings to factory settings. 

2. 

Once the factory setting is done, all segments of the LCD will 
light up briefly, then the time, indoor temperature and humidity 
will be displayed.  

 

Important: 

• 

During factory setting, all signals from the transmitters are lost. 
In order to receive the transmission signals from the 
transmitters, please refer to “

Setting up

” above to set the 

initial reception signal again. 

 

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting mode anytime during the manual setting, 
press the MAX/MIN / RESET button.  

 

OUTDOOR TRANSMITTER AND POOL SENSOR 
SEARCH MODE 

If the transmitters are lost due to disturbances, interferences, 
transmitting distance, etc., a manual transmitter search can be 
started.  
 
 
 
 

 

1. 

Press the + button to select the transmitter.  

2. 

“LEARN” appears in the display of the selected transmitter. 

3. 

Press the SET button to start the search. 

4. 

The reception symbol will be flashing. 

5. 

As soon as the transmitter is found, the temperature appears 
and the reception symbol stays in the display.  

 

INDOOR TEMPERATURE / HUMIDITY AND DEW POINT 
DATA 

The indoor temperature and humidity are detected automatically and 
displayed on the second section of the LCD.

 

 

 

 

 

    

  

 

 

 

 

 

 

 
 

 

 

To display the dew point temperature, press the MAX/MIN / RESET

 

button 3 times.  
 
 
 
 
 
DEW POINT appears in the display. 
The device will automatically quit the dew point mode if no button is 
pressed for a lengthy period (30 seconds) or press the MAX/MIN / 
RESET button again to return to the actual display.  

 

Note: 

The dew point value is based on calculation of the indoor 
temperature and humidity data. 

 

OUTDOOR TEMPERATURE AND POOL 
TEMPERATURE 

The last two LCD section shows the outdoor temperature, pool 
temperature and reception signals.

 

 
 

 

  

 

  

 

 

 
 

 

 

 

 
 

TOGGLING AND RESETTING THE MIN/MAX DATA 

 

TO VIEW THE MIN/MAX DATA AND DEW POINT 

1. 

Press the MAX/MIN / RESET button the indoor temperature 
and humidity and the outdoor temperature and pool 
temperature (MIN) appear.  

2. 

Press the MAX/MIN / RESET

 

button again the maximum 

indoor temperature and humidity and the outdoor temperature 
and pool temperature (MAX) appear.  

3. 

Press the button MAX/MIN / RESET again the dew point 
appears (DEW-POINT).  

4. 

The instrument will automatically quit the MAX/MIN mode if no 
button is pressed for a lengthy period (30 seconds) or press 
the MAX/MIN / RESET button again to return to the actual 
display.  

 

TO RESET THE MIN/MAX DATA

  

Press and hold MAX/MIN / RESET

 

button for 3 seconds to reset 

all the indoor, outdoor and pool values to current values at the 
same time. 

 

TRANSMITTERS 

The outdoor data are measured and transmitted every 10 seconds. 
The range of the transmitter is may be affected by the outdoor 
temperature. At cold temperatures the transmitting distance may be 
decreased. Please bear this in mind when placing the transmitters. 

 

868 MHz RECEPTION: 

If the outdoor data are not being received within three minutes after 
setting up (or outdoor display always show “- -. -” in the outdoor 
sections of the temperature station during normal operation), please 
check the following points: 
1. 

The distance of the temperature station or transmitters should 
be at least 2 meters away from any interfering sources such 
as computer monitors or TV sets. 

2. 

Avoid placing the transmitters onto or in the immediate 
proximity of metal window frames. 

3. 

Using other electrical products such as headphones or 
speakers operating on the 868MHz-signal frequency may 
prevent correct signal transmission or reception. Neighbors 
using electrical devices operating on the 868MHz-signal 
frequency can also cause interference. 

 

Note:

 

 

When the 868MHz signal is received correctly, do not re-open the 
battery cover of either the transmitter or temperature station, as the 
batteries may spring free from the contacts and force a false reset. 
Should this happen accidentally then reset all units (see “

Setting up

” 

above) otherwise transmission problems may occur. 

 

The transmission range is around 100 meters from the temperature 
station to the outdoor transmitter (in open space) and 25 meters to 
the pool sensor (in water). However, this depends on the surrounding 
environment and interference levels. If no reception is possible 
despite the observation of these factors, all system units have to be 
reset (see “

Setting up

 

above). 

 

POSITIONING THE TEMPERATURE STATION 

The temperature station comes attached with a folding stand, which 
provides the option of table standing or wall mounting the unit. Before 
wall mounting, please check that the outdoor temperature can be 
received from the desired locations. 

 

Foldout table stand: 

The foldout table stand leg is located on the 
backside. Pull the stand out from the bottom 
center edge of the temperature station, below 
the battery compartment. Once the foldout table 
stand is extended, place the temperature station 
in an appropriate location. 
 
 

 

To wall mount:

 

1. 

Fix a screw (not supplied) into the desired 
wall, leaving the head extended out by 
about 5mm.  

2. 

Place the temperature station onto the 
screw, using the hanging hole on the 

backside. Gently pull the temperature station down to lock the 
screw into place. 

 

POSITIONING THE OUTDOOR TRANSMITTER 

Mount the transmitter at a sheltered place. Avoid 
direct rain and sunshine. 

  

The outdoor transmitter is supplied with a holder 
that may be attached to a wall with the two screws 
supplied. The outdoor transmitter can also be 
position on a flat surface by securing the stand to 
the bottom to the outdoor transmitter.   
 
 
 

 

To wall mount:  

1. 

Secure the bracket onto a desired wall 
using the screws and plastic anchors. 

2. 

Clip the outdoor transmitter onto the 
bracket. 

 

Note:

  

Before permanently fixing the outdoor 
transmitter wall base, place all units in the 
desired locations to check that the outdoor 

temperature readings are receivable. In event that the signal is not 
received, relocate the remote outdoor transmitter or move them 
slightly as this may help the signal reception. 

 

 

POSITIONING THE POOL SENSOR 

Place the pool sensor in any pool or pond to detect the water 
temperature. 

 

Note: 

In event that the signal is not received, 
relocate the remote pool sensor or 
move it slightly as this may help the 
signal reception. 
 

 

 

 
CARE AND MAINTENANCE  

• 

Clean the instrument and the transmitters with a soft damp 
cloth. Do not use solvents or scouring agents. Protect from 
moisture.

 

• 

Remove the batteries if you do not use the product for a 
lengthy period. 

 

 

BATTERY REPLACEMENT 

• 

Replace the batteries of the temperature station when the 
battery symbol appears in the indoor values display. 

• 

Replace the batteries of the outdoor transmitter when the 
battery symbol appears in the outdoor temperature display of 
the temperature station and/or in the display of the outdoor 
transmitter.

 

• 

Replace the batteries of the pool sensor when the battery 
symbol appears in the pool temperature display of the 
temperature station and/or in the display of the pool sensor.

 

 

Please note: 

When the batteries are changed, the contact between outdoor 
transmitter, pool sensor and basic station must be restored – 
so always insert new batteries into the three devices or start a 
manual transmitter search.  

 

• 

The manuals settings will remain unchanged. 

 

MALFUNCTION 

 

Problems 

Troubleshooting 

No indication on 
the temperature 
station 

• 

Ensure batteries polarity are correct 

• 

Change batteries

 

No transmitter 
reception  
Display "---"    
 

• 

Start a manual transmitter search 

• 

Check batteries of external 
transmitters (do not use 
rechargeable batteries!) 

• 

Restart the transmitters and 
temperature station as per the 

Temperature 
transmitter 
reception 
signal

 

Outdoor 

temperature 

in °C or °F

Indoor 

temperature 

in °C/°F

Dew point 

temperature 

in °C/°F

Minutes 
(flashing)

 

Hours 

(flashing)

Flashing 

Flashing 

Flashing

Flashing 

Pool 

temperature 

in °C or °F

Pool sensor 
reception 
signal

 

“LEARN” icon

Reception 
signal flashing 

Reviews: