background image

 

50 

TO RESET TEMPERATURE MIN/MAX DATA

  

Press and hold 

MIN/MAX

 key for 3 seconds to reset all the indoor and outdoor 

temperature to current temperatures. 

 

ABOUT THE THERMO-HYGRO TRANSMITTER 

The range of the thermo-hygro transmitter may be affected by the temperature. At cold 
temperatures the transmitting distance may be decreased. Please bear this in mind when 
positioning the transmitters. Also the batteries may be reduced in power for the thermo-hygro 
transmitter. 

 

CHECKING FOR 868MHz RECEPTION 

If the outdoor temperature and humidity data are not being received within three minutes 
after setting up (or outdoor display always shows “- -.-” in the outdoor section of the weather 
station during normal operation), please check the following points: 
1. 

The distance of the weather station or transmitters should be at least 2 meters away 
from any interfering sources such as computer monitors or TV sets. 

2. 

Avoid placing the transmitters onto or in the immediate proximity of metal window 
frames. 

3. 

Using other electrical products such as headphones or speakers operating on the 
868MHz-signal frequency may prevent correct signal transmission or reception. 
Neighbors using electrical devices operating on the 868MHz-signal frequency can 
also cause interference. 

 

Note:

 

 

When the 868MHz signal is received correctly, do not re-open the battery cover of either the 
transmitter or weather station, as the batteries may spring free from the contacts and force a 

Summary of Contents for 35.1113.IT

Page 1: ...ant details about its first use and how to operate it and get advice in the event of faults Following the instruction manual for use will prevent damage to the device and loss of your statutory rights...

Page 2: ...s with time and date received All MIN MAX recordings can be reset Indoor and outdoor humidity display in RH Weather forecast with weather tendency indicator Relative air pressure history for the past...

Page 3: ...sible to prevent damage caused by a leaking battery Never use a combination of old and new batteries together or batteries of different types Wear chemical resistant protective gloves and glasses when...

Page 4: ...nsmitter Remote transmission of outdoor temperature and humidity to weather station by 868MHz Alternately display the outdoor temperature and humidity readings on LCD Wall mounting case Mounting at a...

Page 5: ...ries observing the correct polarity see battery compartment marking 3 Replace the battery cover on the unit TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION The weather station uses 2 x C IEC L...

Page 6: ...tes of powering up the transmitter insert the batteries in the weather station see To install and replace batteries in the weather station above Once the batteries are in place all segments of the LCD...

Page 7: ...the radio controlled time is a Cesium Atomic Clock operated by the Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than one second in one million years The time...

Page 8: ...s please place the unit close to a window and or point its front or back towards the Frankfurt transmitter During nighttime the atmospheric disturbances are usually less severe and reception is possib...

Page 9: ...outdoor MIN MAX temperature To decrease change values in setting modes Press and hold for 3 seconds to reset ALL indoor outdoor minimum maximum temperature recordings to current readings To stop the a...

Page 10: ...Indoor humidity display in RH Low battery indicator weather station Weather forecast icon Air pressure history bar graph Outdoor data signal reception indicator Weather tendency indicator Low battery...

Page 11: ...wing settings can be changed when pressing and holding the SET key LCD contrast setting Time zone setting Time reception ON OFF setting Daylight saving time DST ON OFF setting Manual time setting Cale...

Page 12: ...enter the Time Reception ON OFF Setting TIME RECEPTION ON OFF SETTING In area where reception of the DCF 77 time signal is not possible the DCF 77 time reception function can be turned OFF The clock w...

Page 13: ...saving time DST function can be set ON OFF Default setting is 1 ON 1 The digit 1 will start flashing on the LCD 2 Use the or MIN MAX key to turn OFF 0 OFF the daylight saving function 3 Confirm with t...

Page 14: ...he unit will still try and receive the signal despite it being manually set When it does receive the signal it will change the manually set time into the received time During reception attempts the DC...

Page 15: ...ng Use the or MIN MAX key to set the date Keep holding the key allows the value to advance faster 7 Confirm with the SET key and exit the manual setting Note The weekday is automatically displayed abo...

Page 16: ...m icon represents that the alarm is ON The duration of alarm sounding is 2 minutes Press any key will stop the alarm sound WEATHER FORECASTING ICONS The weather icons in the second section of LCD can...

Page 17: ...ta at a constant altitude and therefore result in a more accurate forecast Common to weather forecasting absolute accuracy cannot be guaranteed The weather forecasting feature is estimated to have an...

Page 18: ...d is expected to change For example if the indicator is pointing downwards together with cloud and sun icons then the last noticeable change in the weather was when it was sunny the sun icon only Ther...

Page 19: ...getting better due to the increase of air pressure If the bars go down it means the air pressure has dropped and the weather is expected to get worse from the present time 0h Note For accurate baromet...

Page 20: ...indoor and outdoor temperature sequentially Note the outdoor MIN MAX temperature records will also display the recorded time and date Outdoor humidity in RH Outdoor reception icon Outdoor temperature...

Page 21: ...always shows in the outdoor section of the weather station during normal operation please check the following points 1 The distance of the weather station or transmitters should be at least 2 meters...

Page 22: ...ation provides the option of table standing or wall mounting the unit Before wall mounting please check that the outdoor data can be received from the desired locations To wall mount 1 Fix a screw not...

Page 23: ...nto the bracket Note Before permanently fixing the thermo hygro to the wall base pace all units in the desired locations to check that the outdoor temperature and humidity readings are receivable In e...

Page 24: ...nd the weather station Check if there is any source of interference No DCF reception Time reception setting ON Choose another place for the weather station Manual time setting Wait for attempted recep...

Page 25: ...posal SPECIFICATIONS Temperature measuring range Indoor 9 9 C to 59 9 C with 0 1 C resolution OF L displayed if outside this range Outdoor 39 9 C to 59 9 C with 0 1 C resolution OF L displayed if outs...

Page 26: ...o part of this manual may be reproduced without written consent of TFA Dostmann The technical data are correct at the time of going to print and may change without prior notice DECLARATION OF CONFORMI...