background image

Alarm signal

When a set weather alarm condition has been triggered, that particular alarm
will sound for 120 seconds. The corresponding value, “HI AL” or “LO AL” and
the alarm symbol are flashing until the weather condition doesn’t meet the user
set level. Press any key to mute the alarm. 

Example

Dew point high alarm was triggered:

5.5 Min/Max Mode

While in Normal Mode, press the 

MIN/MAX

key to enter the maximum mode.

In the maximum reading Mode, press the + key to display the following maxi-
mum values together with the time and date stamp when these values were
recorded. Press 

SET

key while the corresponding maximum value is displayed to

reset to the current reading together with the current time and date. 

1. 

Indoor humidity maximum

2. 

Indoor temperature maximum

3. 

Outdoor humidity maximum

4. 

Outdoor temperature maximum 

5. 

Wind chill temperature maximum

6. 

Dew point temperature maximum

7. Pressure 

maximum

8. 

Wind speed maximum 

9. 

Gust speed maximum

10.  1Hour rain maximum
11.  24 hour rain maximum
12.  Week rainfall maximum
13.  Month rainfall maximum

While in Normal Mode, press twice the 

MIN/MAX

key to enter the minimum

mode.

In the minimum reading Mode, press the 

+

key to display the following maxi-

mum values together with the time and date stamp when these values were
recorded. Press 

SET

key while the corresponding minimum value is displayed to

reset to the current reading together with the current time and date.

1.   Indoor humidity minimum
2.   Indoor temperature minimum
3.   Outdoor humidity minimum
4.   Outdoor temperature minimum 
5.   Wind chill temperature minimum 
6.   Dew point temperature minimum
7.   Pressure minimum

STRATOS – 

Wireless weather station

28

6. Specifications

Transmission distance in open field:

100 meter max. 

Frequency:   

868MHz  

Measuring interval 
thermo-hygro sensor:

48 sec

Alarm duration:   

120 sec

Temperature:

Measuring unit:                           °C/°F
Measuring range:
outdoor:   

-40°…+65°C 
-40°…+149°F

indoor:     

0°…+60°C
32°…+140°F 
(show OFL if outside range)

Resolution:    

0.1°C

Accuracy:    

±1°C

Humidity

Measuring unit:  

%RH

Measuring range:   

10%...99% RH 

Resolution:

1%

Accuracy:   

±5% for 20...80% RH

Rain volume

Measuring unit:                             mm/inch  
Rain volume display:   

0 - 9999mm
0-393.6 inch  
(show OFL if outside range)

Resolution:    

0.1mm (if rain volume < 1000mm)
1mm  (if rain volume > 1000mm)

Wind speed 

Measuring unit:

km/h, m/s, mph, knots, Beaufort

Wind speed :    

0~180km/h / 0-50 m/s, 0-111.8 mph 
(show OFL if outside range)

Atmospheric pressure

Measuring unit:

hPa / inHg

Measuring range:

919hPa – 1080hPa
27.17-31.90 inHg

Resolution:

0.1hPa

Accuracy:

±1.5hPa 

Power consumption

Base station:  

3 x AA 1.5V LR6 Alkaline batteries

Remote sensor:  

2 x AA 1.5V LR6 Alkaline batteries

Battery life:  

About 12 months for base station            
About 24 months for thermo-hygro sensor

STRATOS – 

Wireless weather station

29

digit flashing

digit flashing

digit flashing

TFA_No_35.1077_Anleitung_web  31.01.2007  17:40 Uhr  Seite 8    (Schwarz/Process Black Bogen)

Summary of Contents for 35.1077

Page 1: ...mener dans un site appropri de r cup ration ou chez votre revendeur selon les sp cifica tions nationales et locales Attenzione Le batterie scariche e apparecchi elettrici smessi non devono essere smal...

Page 2: ...lation 20 3 2 Mounting 22 4 LCD display 24 4 1 LCD overview 24 4 2 Weather forecast 25 4 3 Weather forecast tendency indicator 25 4 4 Storm warning indicator 25 5 Program modes 26 5 1 Quick display mo...

Page 3: ...Windchill factor and dewpoint Programmable alarm functions for certain weather conditions like temperature alarm storm warning Maximum and minimum values with time and date of recording Radio control...

Page 4: ...or 4 seconds If the LED doesn t light up make sure the battery is inserted the correct way After the thermo hygro sensor is powered up the sensor will transmit weather data for 24s and then the sensor...

Page 5: ...ay unit 1 Base station With the foldable leg at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by the hanging hole at the back of the...

Page 6: ...er setting compared to an area where the air pressure is stagnant For example if 4hPa is selected then there must be a fall or rise in air pressure of at least 4hPa before the weather station will reg...

Page 7: ...And there are five program modes available Quick Display Mode Setting Mode Alarm Mode History Mode and Min Max Mode The program mode can be exited at any time by either pressing the HISTORY key or wa...

Page 8: ...mum value is displayed to reset to the current reading together with the current time and date 1 Indoor humidity minimum 2 Indoor temperature minimum 3 Outdoor humidity minimum 4 Outdoor temperature m...

Page 9: ...reach of children The product is not to be used for medical purpose or for public information but is determined for home use only Improper use or unauthorized opening of housing will mean the loss of...

Reviews: