TFA 31.5011.10 Instruction Manual Download Page 9

17

16

AIR CO

2

NTROL UP Single Beam

– CO

2

Monitor

1. Delivery contents

• CO

2

Monitor

• USB-Type-C-1,5 m cable and power adaptor
• Instruction manual

2. Range of application and all the benefits of your new instrument at a

glance

• For monitoring the CO

2

concentration in buildings, where people are 

present, eg: schools, offices, public facilities

• Single Beam NDIR Sensor
• Large CO

2

display with extended traffic light indication (green/yellow/

blue/red)

• Display of indoor temperature (°C/°F) and humidity
• Memory of the highest and lowest values of CO

2

, temperature and humi-

dity

• Alarm function for CO

2

concentration

• High contrast display with 4 brightness levels 
• Manual calibration function for CO

2

sensor

• Power connection via USB Type-C cable and power supply (included) or

a suitable USB power source

3. For your safety

• This product is exclusively intended for the range of application described

above. It should only be used as described within these instructions. 

• Unauthorized repairs, alterations or changes to the product are prohibited.

Caution!

Risk of electrocution!

• Connect the device using the USB cable and the supplied power supply to

a mains socket installed within your country’s electrical safety regulations
and with a correct mains voltage (see nameplate) or connect the device
via the USB cable to a suitable USB power source such as a computer,
notebook.

• The mains socket must be located near the equipment and it must be 

easily accessible.

• Unplug the device immediately if any fault occurs.
• The device and the power adapter must not come into contact with water

or moisture. Only suitable for indoor use.

AIR CO

2

NTROL UP Single Beam

– CO

2

Monitor

• Do not use the device if the housing, the USB cable or the power adaptor

are damaged.

• Operate the device out of reach of persons (including children) who can-

not fully appreciate the potential risks of handling electrical equipment.

• Connect the USB cable to the device and the power adaptor first and then

plug the power adapter into the socket.

• Route the USB cable lead so that it does not come into contact with sharp-

edged or hot objects.

Important information on product safety!

• Do not expose the device to extreme temperatures, vibrations or shocks.

Avoid direct sunshine. 

• The instrument is not unbreakable. In case of falling down parts can

break.

4. Elements

A: LCD display (Fig. 1):

A 1: 

CO

2

alarm limit

A 2: 

CO

2

indication

A 3: 

Display of minimum values

A 4: 

CO

2

value > 2000 ppm

A 5: 

Extended traffic light indication

A 6: 

Indoor temperature and humidity 

A 7: 

CO

2

alarm symbol

A 8: 

Display of maximum values

B: Buttons (Fig. 1+2):

B 1:

POWER/LIGHT 

sensor button

B 2:

DOWN/CALIBRATE 

button

B 3:

MEM 

button

B 4:

CO

2

SET 

button

B 5:

CO

2

ALARM 

button

B 6:

UP/°C/°F 

button

B 7:

RESET 

button

C: Housing (Fig. 3):

C 1:

USB port

TFA_No. 31.5011_Anleit_10_22  18.10.2022  10:40 Uhr  Seite 9

Summary of Contents for 31.5011.10

Page 1: ...Bedienungsanleitung Instruction manual Instruction manuals www tfa dostmann de en service downloads instruction manuals Kat Nr 31 5011 10 24 TFA_No 31 5011_Anleit_10_22 18 10 2022 10 40 Uhr Seite 1...

Page 2: ...r future reference p Nous vous remercions d avoir choisi l appareil de la soci t TFA Avant d utiliser votre appareil Veuillez lire attentivement le mode d emploi Le mode d emploi est joint l appareil...

Page 3: ...ncias de seguridad Guarde estas instrucciones de uso en un sitio seguro j D kujeme e jste si vybrali v robek zna ky TFA P ed pou it m N sleduj c instrukce k pou it t te velmi pozorn N vod k pou it je...

Page 4: ...struction manuals Nie nale y u ywa urz dzenia inaczej ni zosta o to przedstawione w instrukcji Przestrzegaj c instrukcji unikniecie Pa stwo uszkodze urz dzenia oraz zagro enia utraty swoich ustawowych...

Page 5: ...l inklusive bzw eine geeignete USB Spannungsquelle 3 Zu Ihrer Sicherheit Das Produkt ist ausschlie lich f r den oben beschriebenen Einsatzbereich geeignet Verwenden Sie das Produkt nicht anders als in...

Page 6: ...betriebnahme Wichtiger Hinweis Wenn Sie das Ger t zum ersten Mal verwenden stel len Sie bitte sicher dass die Stromversorgung f r 24 Stunden ununterbro chen angeschlossen ist Das Ger t f hrt dann inne...

Page 7: ...len Wert zur ckgesetzt AIR CO2NTROL UP Single Beam CO2 Monitor 10 Kalibrierung des CO2 Sensors 10 1 Automatische Kalibrierung des CO2 Sensors Der Sensor kalibriert sich automatisch alle 24 Stunden auf...

Page 8: ...ten abzugeben Beachten Sie die aktuell geltenden Vorschriften 14 Technische Daten Spannungsversorgung USB Typ C 1 5 m Kabel und Netzteil inklusive AIR CO2NTROL UP Single Beam CO2 Monitor Input 100 24...

Page 9: ...suitable USB power source such as a computer notebook The mains socket must be located near the equipment and it must be easily accessible Unplug the device immediately if any fault occurs The device...

Page 10: ...he value flashes Press and hold the DOWN CALIBRATE or UP C F button in setting mode for fast mode Confirm the setting with the CO2 SET button The device will automatically quit the setting mode if no...

Page 11: ...g Problem Solution No display on the device Press the POWER LIGHT button for 3 seconds to switch on the device Set the brightness with the POWER LIGHT button Connect the device with USB cable and powe...

Page 12: ...t 172 g device only No part of this manual may be reproduced without written consent of TFA Dostmann The technical data are correct at the time of going to print and may change without prior notice Th...

Reviews: