TFA 30.3018.10.IT Instruction Manual Download Page 1

 

32 

WIRELESS 868 MHz TEMPERATURE 

STATION

 

 

 

Instructions Manual 

Cat. No. 30.3018.10.IT

 

 

Thank you for choosing this wireless temperature 
station from TFA. 

 

 

BEFORE YOU USE IT 

Please be sure to read the instruction manual 
carefully.

 

This information will help you to familiarise yourself with 
your new device, learn all of its functions and parts, find 
out important details about its first use and how to operate 
it, and get advice in the event of faults. 
Following the instruction manual for use will prevent 
damage to the device and loss of your statutory rights 
arising from defects due to incorrect use. 

We shall not be liable for any damage occurring as a 
result of not following these instructions. 
Please take particular note of the safety advice! 
Please look after this manual for future reference.

 

 

SCOPE OF SUPPLY: 

• 

Temperature station (basic unit)

 

• 

Outdoor transmitter

 

• 

Instruction manual  

 
 
 
 
 
 

Summary of Contents for 30.3018.10.IT

Page 1: ...nd out important details about its first use and how to operate it and get advice in the event of faults Following the instruction manual for use will prevent damage to the device and loss of your statutory rights arising from defects due to incorrect use We shall not be liable for any damage occurring as a result of not following these instructions Please take particular note of the safety advice...

Page 2: ...displayed as RH with MIN MAX recordings All MIN MAX temperature recordings show date and time received All MIN MAX recordings can be reset Indoor comfort level indicator happy or sad face icons Can take up to two outdoor transmitters LCD contrast setting Low battery indicator Wireless transmission at 868 MHz Signal reception intervals at 4 seconds Wall mounting or table standing FOR YOUR SAFETY Th...

Page 3: ...mful acids Low batteries should be changed as soon as possible to prevent damage caused by a leaking battery Never use a combination of old and new batteries together or batteries of different types Wear chemical resistant protective gloves and glasses when handling leaked batteries Important information on product safety Do not expose the instrument to extreme temperatures vibration or shock The ...

Page 4: ...35 ELEMENTS THE TEMPERATURE STATION LCD Display Function Keys Foldable stand Hanging Hole Battery Cover ...

Page 5: ...PLACE BATTERIES IN THE TEMPERATURE TRANSMITTER The temperature transmitter uses 2 x AAA IECLR3 1 5V batteries To install and replace the batteries please follow the steps below 1 Slide the battery cover downwards and remove 2 Insert the batteries observing the correct polarity see marking 3 Replace the battery cover This socket is only for the external probe Do not apply power plug to it Optional ...

Page 6: ... polarity see battery compartment marking 3 Replace battery cover Battery replacement Replace the batteries when the battery symbol of the temperature station appears near the indoor temperature display When the batteries of the transmitter are used up the low battery icon appears near the outdoor temperature display Note In the event of changing batteries in any of the units all units need to be ...

Page 7: ...re not displayed on the LCD after 60 seconds remove the batteries and wait for at least 60 seconds before reinserting them Once the indoor data is displayed user may proceed to the next step 3 After the batteries are inserted the temperature station will start receiving data signal from the transmitter The outdoor temperature data channel 1 and 2 should then be displayed on the Temperature station...

Page 8: ...till be displayed The temperature probe can be connected to the temperature transmitter anytime There is no need to reset the units The temperature station will automatically detect the temperature probe and will display the temperature probe data in channel 2 WHEN MORE THAN ONE TRANSMITTER IS USED 1 User shall remove all the batteries from the Temperature Station and transmitters and wait 60 seco...

Page 9: ...the temperature probe channel 2 will display 5 Insert the batteries in the second transmitter as soon as the outdoor temperature readings from the first transmitter are displayed on the Temperature Station Note User shall insert the batteries into the second transmitter within 45 seconds after the temperature station displays the information of the first transmitter Or immediately after reception ...

Page 10: ...ould be no reception problems within a 1500km radius of Frankfurt Once the outdoor temperature is displayed on the temperature station the DCF tower icon in the clock display will start flashing in the upper left corner This indicates that the clock has detected that there is a radio signal present and is trying to receive it When the time code is received the DCF tower becomes permanently lit and...

Page 11: ... is adequate to keep the accuracy deviation below 1 second FUNCTION KEYS Temperature Station The temperature station has four easy to use function keys SET key Setting Used to enter the set mode for the following functions LCD contrast Time zone Time Reception ON OFF 12 24 hour display Manual time Year Date and C F settings The year can only be displayed in the set mode not displayed in normal mod...

Page 12: ... the current minimum maximum outdoor temperature Press for around 3 seconds to reset the outdoor maximum and minimum temperature records will reset all temperatures to current level of the relative transmitter being reset each transmitter s data must be reset separately Note the time date information of MIN MAX data will be reset to default time as well Change minute month day in setting modes Not...

Page 13: ...on shows that a reception is currently taking place MANUAL SETTINGS The following manual settings can be changed when pressing the SET key for LCD contrast setting Time zone setting Time reception ON OFF setting 12 24 Hour setting Time Low battery indicator temperature station Outdoor reception signal Indoor Temperature in C or F Outdoor Temperature in C or F Calendar Outdoor transmitter Identific...

Page 14: ...f contrast desired 2 Press the SET key to confirm and enter the Time Zone setting or exit the setting mode by pressing the CH key TIME ZONE SETTING The time zone default of the Temperature Station is 0 To change to another time zone 1 Press the SET key after completing the LCD contrast setting in order to enter the time zone setting flashing 2 Using the IN key set the time zone The range runs from...

Page 15: ...tart flashing on the LCD 2 Use the IN key to turn OFF the time reception function 3 Confirm with the SET key and enter the 12 24 Hour Display setting or exit the setting mode by pressing the CH key Note If the Time Reception function is turned OFF manually the clock will not attempt any reception of the DCF time as long as the Time Reception OFF function is activated The Time Reception icon will n...

Page 16: ...n be manually set The clock will then work as a normal Quartz clock To set the clock 1 The hour and minutes digits start flashing in the time display section 2 Use the IN key to adjust the hours and the OUT key to adjust the minutes If you hold the key while you adjust the hours move 1 hour and the minutes move 5 minutes 3 Confirm with the SET key and enter the Calendar Setting or exit the setting...

Page 17: ... IN key set the year required The range runs from 2006 to 2039 default is 2006 2 Press the SET key to enter the month and date setting mode 3 Press the IN or OUT key to set the date and the OUT or IN key to set the month required 4 Confirm with the SET key and enter the Snooze setting or exit the setting mode by pressing the CH key SNOOZE SETTING Important The snooze setting in this temperature st...

Page 18: ...ting or exit the manual setting modes WEATHER FORECASTING ICON SENSITIVITY SETTING Important The weather forecast sensitivity setting in this temperature station will not have any effect in this unit performance This features is only available in enhance model with weather forecast feature Press the SET key to finish and exit the manual setting mode INDOOR HUMIDITY WITH COMFORT LEVEL INDICATOR The...

Page 19: ...temperature and humidity data and the times at which they were recorded press the IN key Once to show the minimum temperature and humidity values with time and date recorded Twice to show the maximum temperature and humidity values with time and date recorded Three times to return to the current time date temperature and humidity levels Note the Time date information is only available for the MIN ...

Page 20: ...m temperature data and the times at which they were recorded press the OUT key Once to show the minimum temperature value with time and date recorded Twice to show the maximum temperature value with time and date recorded Three times to return to the current time date and temperature level 2 To toggle between channels press the CH key Once to show channel 2 from optional probe Twice to show channe...

Page 21: ...ter 1 from transmitter 1 probe Twice to show transmitter 2 Three times to return to transmitter 1 2 Use OUT key to view the MIN MAX temperature data for the selected transmitter 3 To reset the minimum and maximum temperature data and the times at which they were recorded press the OUT key continuously for about 3 seconds This will reset the MIN MAX data recorded to the current time date and temper...

Page 22: ...or speakers operating on the same signal frequency 868MHz may prevent correct signal transmission and reception 4 Neighbors using electrical devices operating on the 868 MHz signal frequency can also cause interference Note When the 868MHz signal is received correctly do not re open the battery covers of either the transmitter or Temperature Station as the batteries may spring free from the contac...

Page 23: ... be received from the desired locations To wall mount 1 Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm 2 Fold the stand of the temperature station by pushing inward and hang it onto the screw Remember to ensure that it locks into place before releasing POSITIONING THE OUTDOOR TEMPERATURE TRANSMITTER The sensor is supplied with a holder that may be att...

Page 24: ...wever affect the transmission range If for example the unit is attached to a piece of metal it may then either reduce or increase the transmitting range For this reason we recommend not placing the unit on any metal surfaces or in any position where a large metal or highly polished surface is in the immediate proximity garage doors double glazing etc Before securing in place please ensure that the...

Page 25: ...and temperature station as per the manual Choose another place for the transmitter and or the temperature station Reduce the distance between the transmitter and the temperature station Check if there is any source of interference No DCF reception Time reception setting ON Choose another place for the temperature station Manual time setting Wait for attempted reception during the night Incorrect d...

Page 26: ...duct with other household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment in order to ensure environmentally compatible disposal SPECIFICATIONS Temperature measuring range Indoor 9 9ºC to 59 9ºC with 0 1ºC resolution 14 2 F to 139 8 F with 0 2 F resolution OF L displayed if outside this range Outdoor 3...

Page 27: ...ansmitter 41 x 19 x 128mm TFA Dostmann GmbH Co KG Zum Ottersberg 12 D 97877 Wertheim No part of this manual may be reproduced without written consent of TFA Dostmann The technical data are correct at the time of going to print and may change without prior notice DECLARATION OF CONFORMITY Herewith we declare that this wireless transmission device does comply with the essentials requirements of R TT...