Instruction
manual
FHP
2
page
12
___________________________________________________________________________
5. Remarks with respect to the determined use
The pump must be positioned on an even surface with a max. angle of 15°.
In combination with a 2 m high-pressure hose it is not possible to work in a cable trench.
For this application at least a 3m high-pressure hose is needed.
5.1. Operation of the unit
First roll out the hose completely. Afterwards you have to connect the crimping/cutting
head to the high pressure hose (Pos.-No. 5).
Attention
Don’t actuate the pump without the crimping head.
Attention
Before operating the unit the oil level must be checked and adjusted if
necessary.
2.) Remove the hook (Pos.-No. 2) and bring the remote head into position.
3.) Actuate the pump lever (Pos.-No. 1) continuously until the remote head has terminated
the intended operation.
After this process has been completed the release button must be actuated to return the
piston into its starting position.
5.2. Explanation of the application range
The pump can be operated with the all Klauke crimping and cutting heads:
5.3. Mounting instructions
The remote heads must be mounted on the hose by retracting the sleeve of the coupling
and pushing it onto the nipple.
5.4. Service and maintenance instruction
The hydraulic pump must be cleaned and dried after each use. The pump is basically
maintenance free, only the oil level must be checked regularly and it has to be inspected
for possible damages and wear.
Check the oil level of the pump unit. If the oil level proves to be unsatisfactory additional
oil has to be added. To do that open the oil filler plug (Pos.-No. 4) and fill in the oil. After
servicing the oil filler plug must be screwed on again.
The hydraulic hose (Pos.-No. 5) and the armature must be checked for damage and
leakage.
I