EK6FTLT and EK6FTLX Battery-powered Crimping Tools

Operation

•  Inspect tool and dies before use. Replace any 

worn or  damaged parts. A damaged or improp-

erly  assembled tool can break and strike nearby 

personnel. 

•  Carrying strap is for carrying only, not to be used to 

hang or suspend tool. 

Failure to observe these warnings could result in 

severe injury or death.

Electric shock hazard:
This tool is not insulated. When using 

this unit on or near energized electri-

cal lines, use proper personal protec-

tive equipment.
Failure to observe this warning could 

result in severe injury or death.

Wear eye protection when operating 

or servicing this tool. 
Failure to wear eye protection could 

result in serious eye injury from flying 

debris or hydraulic oil. 

Pinch points:
•  Remove battery before changing 

dies, adapters, or jaws.

•  Keep hands away from the crimp-

ing tool head when crimping.

Failure to observe these warnings 

could result in severe injury or death.

•  Do not use this tool for continuous use. After 30 to 

40 cycles, allow the tool to cool for 15 minutes.

•  Do not secure this tool in a vise. This tool is 

designed for hand-held operation.

•  This tool may be used in damp or wet environ-

ments; however, air-drying is recommended before 

use if the tool becomes soaked. Damage may result 

when the tool is operated prior to thorough drying 

when electrical components are soaked.

•  Use this tool for the manufacturer’s intended 

purpose only.

Failure to observe these precautions may result in 

injury or property damage.

Charging the Battery

Read the instructions supplied with the battery charger.

LED Work Light (white)

This LED automatically turns on when the trigger is 

pulled. It remains on for 10 seconds after the trigger is 

released.

LED Indicator (red)

This tool is equipped with a special circuit board incor-

porating several important features to inform the user 

about the current status of the unit. The LED signals in 

the following cases:

What happens

Signal

What it means

Constant light for 20 seconds 

at end of cycle

Battery charge is below 

17 V at beginning of cycle*

Tool will 

not

 start, and 

constant light for 20 seconds 

when trigger is released

Battery charge is below 

16 V at beginning of cycle*

Tool will stop, and constant 

light for 20 seconds after 

trigger is released

Battery voltage drops 

below 13 V during cycle*

Tool will stop, and flashing 

light for 20 seconds when 

trigger is released

 

Motor current exceeds 

20 A during cycle
Circuit has become too hot

Flashing light for 20 seconds 

at end of cycle

 

Send tool in for service

  * Running the battery below 16 V can damage the battery.

Summary of Contents for Greenlee EK6FTLX

Page 1: ...lee Textron Inc 3 17 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com Serial Number E...

Page 2: ...may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note Change or modifications made to this equipmen...

Page 3: ...Failure to observe this warning could result in severe injury or death Wear eye protection when operating or servicing this tool Failure to wear eye protection could result in serious eye injury from...

Page 4: ...electrical components are soaked Use this tool for the manufacturer s intended purpose only Failure to observe these precautions may result in injury or property damage Do not allow anything to conta...

Page 5: ...8 kg Crimping Force 6 2 tons 55 kN Hydraulic Oil 52057878 biodegradable hydraulic fluid Recommended Operating Temperature Range 5 F to 122 F 15 C to 50 C Crimping Capacities Crimping Range Copper 4 AW...

Page 6: ...ed in damp or wet environ ments however air drying is recommended before use if the tool becomes soaked Damage may result when the tool is operated prior to thorough drying when electrical components...

Page 7: ...y become wedged between the nibs of the tool Center the connector between the four nibs before crimping Failure to observe this precaution may cause property damage 2 Pull the trigger to advance the n...

Page 8: ...L YA 2L YA YA L TC YA L 2TC CSW CRA CRB LCAS LCA LCD 54107 54123TB 54207 54223 BLU Long VHCL CTL L LCN YA 2N CLN CLW CRA L CRB L CRA 2L CRB 2L LCB LCC 54933BE 54923BE 54855BE 54880BE BBLU Dual rated...

Page 9: ...y 9 Battery empty tool won t run 10 Real time clock battery low 11 Tool deactivated 12 Service necessary 13 Real time clock not found 14 Bluetooth unit not found 15 16 Pressure sensor not found 17 Bur...

Page 10: ...y from the crimp ing tool head when crimping Failure to observe these warnings could result in severe injury or death Relief valve adjustments must be done by an authorized service center Daily Before...

Page 11: ...at 800 435 0786 for warranty service or repair Motor is inoperative Low or uncharged battery Try known charged battery Inoperative battery may be discharged or may have reached life expectancy Broken...

Page 12: ...8 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc USA Tel 800 435 0786 Fax 800 451 2632 Canada Tel 800 435 0786 Fax 800 524 2853 International Tel 1 815 397 70...

Reviews: