Textron Greenlee CM-1300 Instruction Manual Download Page 13

12

Typical Measurements

Continuity Check

Summary of Contents for Greenlee CM-1300

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...nderstand all of the instructions and safety information in this manual before operating or servicing this tool Lea y entienda todas las instrucciones y la informaci n sobre seguridad que aparecen en...

Page 3: ...ent This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool Observe all of the safety information provided Pu...

Page 4: ...rds or unsafe practices which could result in an injury or property damage The signal word defined below indicates the severity of the hazard The message after the signal word provides information for...

Page 5: ...ndition Use this unit for the manufacturer s intended purpose only as described in this manual Any other use can impair the protection provided by the unit Failure to observe these warnings can result...

Page 6: ...in temperature or high humidity Refer to Specifications Failure to observe these precautions can result in injury and can damage the unit Do not change the measurement function while the test leads a...

Page 7: ...nction is enabled 17 DC measurement is selected 18 AC measurement is selected 19 kHz Kilohertz 20 MHz Megahertz 21 Volts Voltage 22 Amps Amperes 23 Ohms 24 Continuity 25 TRMS True RMS CM 1350 only 26...

Page 8: ...nput Press momentarily to cycle through the display modes as shown in the table below The meter uses its highest voltage or current range for this feature Press and hold to exit this mode PEAK Button...

Page 9: ...1 and displays the result This method is accurate if the input signal is a pure sine wave The Greenlee CM 1300 is an average responding meter The true RMS reading method uses internal circuitry to rea...

Page 10: ...o Greenlee for repair Refer to the instructions under the Warranty 4 Take the reading from the circuit or component to be tested Settings Table Electric shock hazard Contact with live circuits can res...

Page 11: ...rements Current Measurement Clamp Around Wire Notes Clamp the jaw around one conductor only Close the jaw completely to ensure accurate measurement Center the wire in the jaw for highest accuracy Volt...

Page 12: ...und Line Splitter Notes The Greenlee 93 30 Line Splitter is divided One section renders amps the other renders amps multiplied by 10 Close the jaw completely to ensure accurate measurement Center the...

Page 13: ...12 Typical Measurements Continuity Check...

Page 14: ...A 1000 A 401 to 1000 1 9 5 A 2 5 7 A CM 1300 is average sensing RMS calibrated CM 1350 is true RMS sensing Accuracy is specified for sine waves at full scale and non sine waves below half scale For n...

Page 15: ...0 1 0 0 3 1000 V overload protection Peak Hold Accuracy of held value is 3 15 digits Accuracy is unspecified above 750 V peak and above 800 A peak The meter switches to the 750 VAC 1000 VDC or 1000 A...

Page 16: ...0 to 80 relative humidity noncondensing 30 C to 40 C 86 F to 104 F 0 to 75 relative humidity noncondensing 40 C to 50 C 104 F to 122 F 0 to 45 relative humidity noncondensing Altitude 2000 m 6500 maxi...

Page 17: ...clude transient protected electronic circuits inside photocopiers and modems Measurement Category II Local level Appliances portable equipment and the circuits they are plugged into Some examples incl...

Page 18: ...nnect the unit from the circuit 2 Remove the screw from the battery cover 3 Remove the battery cover 4 Replace the battery or batteries Observe polarity 5 Replace the cover and the screw Cleaning Peri...

Page 19: ...18...

Page 20: ...dar mantenimiento a las herramientas y equipo Greenlee Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la informaci n necesaria para evitar riesgos y h bitos poco...

Page 21: ...pr ctica poco segura que podr a ocasionar lesiones o da os materiales Cada uno de los siguientes t rminos denota la gravedad del riesgo El mensaje que sigue a dichos t rminos le indica c mo puede evi...

Page 22: ...incendio No exponga esta unidad ni a la lluvia ni a la humedad No utilice esta unidad si se encuentra mojada o da ada Utilice cables de prueba y accesorios que sean apropiados para la aplicaci n que...

Page 23: ...unidad a ambientes de temperatura extrema o altos niveles de humedad Consulte la secci n Especificaciones De no observarse estas precauciones podr an sufrirse lesiones o da os a la unidad No cambie l...

Page 24: ...valor m ximo 16 Se activa la funci n Hold Retenci n de datos en pantalla 17 Se selecciona medici n de CC 18 Se selecciona medici n de CA 19 kHz Kilohertzios 20 MHz Megaherzios 21 Volts Tensi n 22 Amp...

Page 25: ...a ciclar a trav s de los modos de pantalla seg n se ilustran en la tabla a continuaci n El medidor utiliza su tensi n o escala de corriente m s alta para esta funci n Oprima y mantenga oprimido el bot...

Page 26: ...do El resultado es exacto si la se al de entrada es una onda sinusoidal pura El modelo CM 1300 de Greenlee es un mult metro que responde al valor medio El m todo de lectura de valores eficaces reales...

Reviews: