4-2.
Parallel Operation
The LSG-H Series can be connected in parallel to increase the total power
capacity of a single unit. The LSG-H Series can operate with up to 5 units in
parallel. A single unit is designated as a master unit and any other connected
units as slaves.
Only units of the same type and rating can be used in parallel or alternatively,
the LSG-2100SH booster pack can be used as a slave with the LSG-1050H.
When a master unit is used in parallel operation, to ensure stability, the
response speed will drop down to 1/2 if it was originally 1/1. You can however,
reset the response speed back (or to another value) in the Main>Configure
menu.
4-2-1. Capacity of DC electronic loads
Model
Single Unit
2 Units
3 Units
4 Units
5 Units
LSG-175H
800V
8.75A
175W
800V
17.5A
350W
800V
26.25A
525W
800V
35A
700W
800V
43.75A
875W
LSG-350H
800V
17.5A
350W
800V
35A
700W
800V
52.5A
1050W
800V
70A
1400W
800V
87.5A
1750W
LSG-1050H
800V
52.5A
1050W
800V
105A
2100W
800V
157.5A
3150W
800V
210A
4200W
800V
262.5A
5250W
LSG-1050H
+
LSG-
2100HS*
800V
157.5A
3150W
800V
262.5A
5250W
800V
367.5A
7350W
800V
472.5A
9450W
N/A
* The LSG-2100SH booster packs do not have a control panel.
They can only be used as slaves with a single LSG-2100SH in parallel.
Summary of Contents for LSG-1050H
Page 24: ...14 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6...
Page 185: ...175 7 6 Operating Area 7 6 1 LSG 175H H Range M Range L Range...
Page 186: ...176 7 6 2 LSG 350H H Range M Range L Range...
Page 187: ...177 7 6 3 LSG 1050H H Range M Range L Range...
Page 188: ...178 7 6 4 LSG 2100H H Range M Range L Range...
Page 204: ......