127
3-6-3. Running a BATT Test function
Operation
1.
Press
FUNC
>
Next Manu
[F5]
> BATT
[F2] in
order, and Press BATT [F1] to turn the BATT function
on.
2.
Turn the load on.
See page 87 (
3-1-2.Turning on the Load with the Selected
Function
) for the load on.
The discharge test will keep running with its defined
mode and values until any of the Stop Voltage, Stop
Time or Stop AH settings is detected.
Example:
BATT Test
Function running
Exit
BATT
USB
01/Oct/2018
0.0024
4.90
V
4.994
A
W
50.61
CC, IHVH, 5.0000 A
Stop: 3.00V, 0.20Ah
24.47
0:00:01
0.0019
Ah
Wh
Discharging:
3-6-4. Results of BATT Test function
Description
The BATT Test will return the information of the last
discharge when the Battery stop voltage or stop time or
stop AH was tripped.
Test stop for
Voltage tripped
Exit
BATT
USB
01/Oct/2018
0.0418
2.95
V
0.000
A
W
50.61
CC, IHVH, 5.0000 A
Stop Volt: 3.00V
0.00
0.1778
Ah
Wh
Complete Discharging:
Save
TEST
Result