Technical Specification
INS 034-9
39
4.5
Fuses
A spare mains fuse is supplied in a clip adjacent to the mains terminal block.
see safety note 7
Spare PCB fuses are supplied in a press-seal bag.
see safety notes 7 & 8
Mains 230V
AC
:
T125mA, 250V, 20mm
see safety note 7
Mains 115V
AC
:
T250mA, 250V, 20mm
see safety note 7
F1 (Battery Fuse):
F1A, 250V, 20mm
see safety note 7
F2 (Bell & Strobe Fuse):
F1A, 250V, 20mm
see safety note 7
F3 (L/S & Detector Auxiliary Fuse):
F500mA, 250V, 20mm
see safety note 7
F4 (RKP Auxiliary Fuse):
F500mA, 250V, 20mm
see safety note 7
F5 (Power Supply Output Fuse):
F1.6A, 250V, 20mm
see safety note 7
4.6
Miscellaneous
Internal Speaker (50mm, 16
Ω
Ω
Ω
Ω
)
Low Level Volume:
Adjustable
High Level Volume:
>
90dB at 1m
Loop Response Time
Minimum:
>
200ms
Maximum:
<
800ms
Remote Keypads:
Up to 6
4.7
Safety Notes
1)
Mains voltage is factory set and not adjustable - see label on transformer.
2)
Removal of the transformer is prohibited and will invalidate the warranty.
3)
Only use batteries of the specified type.
4)
Dispose of used batteries safely according to the manufacturer's
instructions.
5)
Locate the battery inside the panel in the space provided.
6)
This equipment is designed for dry indoor use only.
7)
When replacing a fuse always observe the specified rating and type - failure
to do so is dangerous and will invalidate the warranty. Fuses should comply
with IEC 127.
8)
The press-seal bag must NOT be stored inside the panel.