2. Lift detector lid out from the base and off the lugs at the opposite end to the
screw
3. Fix the base to the ceiling between 2.4 m and 3.6 m (8 and 12 ft) from the floor.
For flat mounting use a minimum of 2 screws (DIN 7998) in any of the available
positions
). Rear tamper pull-out needs to be secured to the mounting
surface to meet Grade 3 requirements.
5. Select the desired option settings (
On power-up the detector will temporarily enter an auto-optimisation mode to
adapt to its environment. This will be shown by the LED’s flashing in
sequence. Allow 3 minutes for the optimisation to complete.
During optimisation ensure that there are no obstructions in close proximity
(<1m) to the detector that will not be present during normal operation, as
this could trigger a false masking signal.
The detector is designed to be connected to a single zone on control panels which
feature Triple End-Of-Line compatibility. Alarm, Tamper, Fault and Masking are
signalled on one pair of wires. To aid installation the resistor values can be
selected via the jumpers. All the connections are normally closed. Masking is
Summary of Contents for Premier Elite AM 360DT
Page 1: ...Installation Manual Premier Elite AM 360DT INS622 2 ...
Page 2: ...INS622 2 2 13 Content 1 0 Instruction Manual 3 2 0 EN Installation Sheet 7 ...
Page 4: ...INS622 2 4 13 3 ________________________________________________________ ...
Page 5: ...INS622 2 5 13 ...
Page 13: ...INS622 2 13 13 ...