Programming zone arming and disarming: 

(Note that Zone 7 and 8 has been used as an example) 

AWAY arming Relay1 

Connect relay 1 to Zone 7 with resistor in series to the NC and COM 

 

Go into programming 

 

Go to Zone Setup and press YES 

Use the arrow key and go to zone 7. Press NO to edit and use the arrow key to go to 
MOMENT KEY and select it by pressing YES 

Press YES to go to Attributes 1 and press NO to edit. Use the arrow key to go to INSTANT 
ARM and press NO to Enable it and press YES 

STAY arming Relay2 

Connect relay 2 to Zone 8 with resistor in series to the NC and COM 

 

Go into programming 

 

Go to Zone Setup and press YES 

Use the arrow key and go to zone 8. Press NO to edit and use the arrow key to go to 
MOMENT KEY and select it by pressing YES 

Press YES to go to Attributes 1 and press NO to edit. Use the arrow key to go to PART 1 OMIT 
and press NO to Enable it and press YES 

To exit and save programming: 

Press MENU and the Keypad will ask if you want to exit and log off, Press YES 

 

 

 

 

 

 

 

 

 

 

 

 

 

 