11
2. Starting
PROCEDURE
1. Open the fuel tap.
On a cold engine open the choker.
Note: By a hot engine choke is not required.
2. Tu
rn the engine’s gas control lever on full gas and press the primer 5-6 times for a cold engine.
(If the engine is mounted on a machine with cable-regulated gas, full gas is given).
Turn the thro
ttle cable to “start position” and insert the engine key.
3. Pull the recoil starter gently until you feel resistance in the rope. Then pull quickly and energetic. Do
not at any time let go of the recoil starter but slide it gently back and pull again.
For 230V electric starter.
Plug the cord into the power socket and to the electrical socket on the engine and press the red start
button in order to start the engine. After the engine is started remove the plug from the socket and
the outlet of the engine.
4. Regulate the choker until the engine is running smoothly.
See fig. 1, 2, 3.
3. Operation
OPERATION
1. When the engine has been started move the choke gradually to the right.
2. Adjust the gas to the requested speed.
See fig. 1.
NOTE
Please observe the following during operation.
Exhaustion must not be black. If the exhaustion is black the load is too high or the engine has not
been adjusted correctly.
Unpleasant sound and vibration.
If these appear turn off the engine and adjust it. Contact your dealer
4. Stopping the engine
PROCEDURE
1. Turn the gas control to position
“Low” and engine will stop running.
2.
Turn the fuel tap to the ”off” position
See fig. 2.
Fuel tap
Closed
Closed
Choke
HIGH
LOW