Input Signal
Vin
DMM
(DC_Volt)
GAIN
OUT
IN
SET
R
V
V
2R
=
www.ti.com
Basic EVM Configuration
3
Basic EVM Configuration
This section describes four configurations for the XTR300EVM that enable evaluation of the basic XTR300
functions.
3.1
Voltage Mode Configurations
3.1.1
Single-Ended Output
The first voltage mode configuration creates a single-ended output from a single ended input. The jumper
settings for this configuration are listed in
Table 4
. Connect your load to TB4 between OUT+ and OUT–.
Apply ±15 V to V+ and V–. Apply a 5-V signal to V
IN
. The voltage across TB4 should be 10 V. The voltage
output is calculated by the transfer function shown in
Equation 1
:
(1)
The default EVM configurations set R
GAIN
to 10 k
Ω
and R
SET
to 2.5 k
Ω
.
Table 4. Single Ended Voltage Output Jumper Settings
Jumper
Function
J1
On
J2
On
J3
Off
J4
Off
J5
Off
J6
On
J7
Off
Figure 2. XTR300 Single-Ended Voltage Output Configuration Circuit Drawing
5
SBOU034A – February 2006 – Revised February 2013
XTR300EVM
Submit Documentation Feedback
Copyright © 2006–2013, Texas Instruments Incorporated