Filter
4.11.23 Filter Output Clamp High Register (FILTEROCLPHI)
Address 00060058 – Filter 2 Output Clamp High Register
Address 00090058 – Filter 1 Output Clamp High Register
Address 000C0058 – Filter 0 Output Clamp High Register
Figure 4-28. Filter Output Clamp High Register (FILTEROCLPHI)
23
0
OUTPUT_CLAMP_HIGH
R/W-11 1111 1111 1111 1111
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 4-23. Filter Output Clamp High Register (FILTEROCLPHI) Register Field Descriptions
Bit
Field
Type
Reset
Description
23-0
OUTPUT_CLAMP
_HIGH
R/W
11 1111
1111
1111
1111
Sets the upper limit of filter output value. If calculated filter output exceeds this
threshold, the filter output will be set to OUTPUT_CLAMP_HIGH