background image

1

SLUUC86 – March 2020

Submit Documentation Feedback

Copyright © 2020, Texas Instruments Incorporated

Using the UCC5304EVM-035

User's Guide

SLUUC86 – March 2020

Using the UCC5304EVM-035

Contents

1

Introduction

...................................................................................................................

2

2

Description

....................................................................................................................

3

2.1

Features

..............................................................................................................

3

2.2

I/O Description

......................................................................................................

4

2.3

Jumpers (Shunt) Setting

...........................................................................................

5

3

Electrical Specifications

.....................................................................................................

5

4

Test Summary

................................................................................................................

6

4.1

Equipment

...........................................................................................................

6

4.2

Equipment Setup

....................................................................................................

6

5

Power Up and Power Down Procedure

...................................................................................

9

5.1

Power Up

............................................................................................................

9

5.2

Power Down

.......................................................................................................

11

6

Schematic

...................................................................................................................

12

7

Layout Diagrams

...........................................................................................................

13

8

List of Materials

.............................................................................................................

15

List of Figures

1

Jumpers Installation Position

...............................................................................................

7

2

Bench Setup Diagram and Configuration

.................................................................................

8

3

Example Input and Output Waveforms (Inputs: CH2, Outputs: CH3)

................................................

9

4

Example Input and Output Waveforms, Zoom In on Rise (Inputs: CH2, Outputs: CH3)

.........................

10

5

Example Input and Output Waveforms, Zoom In on Fall (Input: Ch2, Output Ch3)

...............................

11

6

UCC5304EVM-035 Schematic

...........................................................................................

12

7

Top Overlay

.................................................................................................................

13

8

Top Layer

...................................................................................................................

13

9

Bottom Layer

................................................................................................................

14

10

Bottom Overlay

.............................................................................................................

14

List of Tables

1

Test Points and Jumpers

...................................................................................................

4

2

Jumpers Setting

..............................................................................................................

5

3

UCC5304EVM-035 Electrical Specifications

.............................................................................

5

4

Two-Channel Function Generator Settings

..............................................................................

7

5

Oscilloscope Settings

.......................................................................................................

7

6

UCC5304EVM-035 List of Materials

.....................................................................................

15

Summary of Contents for UCC5304EVM-035

Page 1: ...t Diagrams 13 8 List of Materials 15 List of Figures 1 Jumpers Installation Position 7 2 Bench Setup Diagram and Configuration 8 3 Example Input and Output Waveforms Inputs CH2 Outputs CH3 9 4 Example...

Page 2: ...n mode transient immunity CMTI greater than 100 V ns The device has an impressive propagation delay of 28 ns and the tightest part to part delay matching in the industry of less than 5 ns which enable...

Page 3: ...ed with minimized loop area in both the gate driver and power supply loops with bypassing capacitors For detailed device information see the UCC5304 4 A 6 A 5 7 kVRMS Isolated Single Channel Reinforce...

Page 4: ...asured before gate drive resistor TP3 OUT_CAP Output measured at output capacitor TP4 IN Positive input TP5 VDD Output supply positive input TP6 IN Positive input TP7 VDD Output supply positive input...

Page 5: ...not installed IN provided by external signal and this pin is low by default if left open Option A Option B Jumper on J1 2 and J1 1 sets IN low Option C Jumper on J1 2 and J1 3 sets IN high 3 Electrica...

Page 6: ...d Section 3 4 1 Equipment 4 1 1 Power Supplies Two DC power supplies with voltage current above 18 V and 1 A respectively are required for example Agilent E3634A 4 1 2 Function Generators One 2 channe...

Page 7: ...rator Settings Mode Frequency Duty Delay High Low Output Impedance Channel 1 Pulse 200 kHz 50 0 s 3 3 V 0 V High Z 4 2 4 Oscilloscope Setting Table 5 lists the oscilloscope setting Table 5 Oscilloscop...

Page 8: ...function generator channel 1 to TP4 IN and TP8 GND see Figure 2 3 Power supply 1 Connect the positive lead to the current meter input of DMM1 and connect the current meter output of DMM1 to TP12 VCCI...

Page 9: ...DMM1 should be approximately 1mA to 2mA 3 Enable power supply 2 The quiescent current on DMM2 should be approximately 0 75 mA to 2 mA if everything is set correctly 4 Enable the function generator out...

Page 10: ...2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 Figure 4 shows a zoomed in view of the example input and output waveforms Figure 4 Example Inp...

Page 11: ...EVM 035 Figure 5 shows a zoomed in view of the example input and output waveforms Figure 5 Example Input and Output Waveforms Zoom In on Fall Input Ch2 Output Ch3 5 2 Power Down The following list des...

Page 12: ...Schematic www ti com 12 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 6 Schematic Figure 6 UCC5304EVM 035 Schematic...

Page 13: ...ti com Layout Diagrams 13 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 7 Layout Diagrams Figure 7 Top Overlay Figure 8 Top La...

Page 14: ...Layout Diagrams www ti com 14 SLUUC86 March 2020 Submit Documentation Feedback Copyright 2020 Texas Instruments Incorporated Using the UCC5304EVM 035 Figure 9 Bottom Layer Figure 10 Bottom Overlay...

Page 15: ...1 F 50 V 10 X7R 0805 1 C4 Capacitor ceramic 1800 pF 50 V 10 X7R 1206 1 C6 Capacitor ceramic 0 1 F 25 V 10 X7R 0603 1 D1 Diode Schottky 30 V 1 A MicroSMP 1 J1 Header 2 54 mm 3x1 Tin TH 1 R1 Resistor 1...

Page 16: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 17: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 18: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 19: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 20: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 21: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...