Connect the Signal Generators to the EVM (RF Outputs Disabled Until Further Directed)
10
SBAU323A – January 2019 – Revised January 2019
Copyright © 2019, Texas Instruments Incorporated
Setup Procedure
2.6
Connect the Signal Generators to the EVM (RF Outputs Disabled Until Further Directed)
Connect a signal generator to the VIN input of the TSW12D1620EVM-CVAL through a band-pass filter
and attenuator at the SMA connector. This generator must be a low-noise signal type. TI recommends a
Trilithic-tunable band-pass filter to filter the signal from the generator. Configure the signal generator for
147.77 MHz,
–10 dBm.
2.7
Turn On the TSW14DL3200EVM Power and Connect to the PC
1. Turn on the 12-V power supply connected to the TSW14DL3200EVM.
2. Turn on the power switch on the TSW14DL3200EVM.
3. Connect a mini-USB 3.0 cable from the PC to the TSW14DL3200EVM.
4. If the TSW14DL3200EVM has not previously been connected to the PC, follow the on-screen
instructions to automatically install the device drivers. See the
for
specific instructions.
2.8
Turn On the TSW12D1620EVM-CVAL 5-V Power Supply and Connect to the PC
1. Turn on the 5-V power supply to power up the EVM.
2. Turn on the power switch on the TSW12D1620EVM-CVAL.
3. Connect the EVM to the PC with the mini-USB cable.
2.9
Turn On the Clock Signal Generator RF Output
Turn on the RF signal output of the signal generator connected to the DEVCLK input.
2.10 Turn On the Signal Generator RF Outputs