Detailed Description
Copyright © 2011–2017, Texas Instruments Incorporated
Table 6-19. Address and Command Word Bit Distribution (continued)
COMMAND
CODE
COMMAND
COMMENTS
0x19
Test external RF (RSSI at RX input with TX on)
The command code values from
are substituted in
, bits 0 through 4. Also, the most-
significant bit (MSB) in
must be set to 1. (
is same as
, shown here again
for easy reference).
Table 6-20. Address and Command Word Bit Distribution
BIT
DESCRIPTION
BIT FUNCTION
ADDRESS
COMMAND
B7
Command control bit
0 = Address
1 = Command
0
1
B6
Read/Write
0 = Write
1 = Read
R/W
0
B5
Continuous address mode
1 = Continuous mode
R/W
0
B4
Address/Command bit 4
Adr 4
Cmd 4
B3
Address/Command bit 3
Adr 3
Cmd 3
B2
Address/Command bit 2
Adr 2
Cmd 2
B1
Address/Command bit 1
Adr 1
Cmd 1
B0
Address/Command bit 0
Adr 0
Cmd 0
The MSB determines if the word is to be used as a command or address. The last two columns of
show the function of each bit, depending on whether address or command is written.
Command mode is used to enter a command resulting in reader action (initialize transmission, enable
reader, and turn reader on or off).
6.14.1.1 Idle (0x00)
This command issues dummy clock cycles. In parallel mode, one cycle is issued. In SPI mode, eight
cycles are issued. This command should be sent after a Software Initialization command to allow the
command to finish operation.
6.14.1.2 Software Initialization (0x03)
This command starts a power-on reset. After sending this command, the register values change as shown
in
.
(1)
Differs from default at POR
Table 6-21. Register Values After Sending Software
Initialization (0x03)
ADDRESS
REGISTER
VALUE
0x00
Chip status control
0x01
0x01
ISO control
0x21
(1)
0x02
ISO/IEC 14443 B TX options
0x00
0x03
ISO/IEC 14443 A high bit rate options
0x00
0x04
TX timer high byte control
0xC1
(1)
0x05
TX timer low byte control
0xC1
(1)
0x06
TX pulse length control
0x00
0x07
RX no response wait time
0x0E
0x08
RX wait time
0x07
(1)
0x09
Modulator and SYS_CLK control
0x91
0x0A
RX special setting
0x10
(1)