3 Test Setup Diagrams
This section includes general recommendations for S-parameter, noise figure, and two-tone OIP3 setup while
measuring the TRF0206-SP EVM.
3.1 S-Parameter Test Setup
TRF0206-SP EVM
(J4)
TRF0206-SP
(J6)
(J5)
INP
INM
OUTM
OUTP
Vector Network Analyzer
Figure 3-1. S-Parameter Test Setup
Use the following guidelines for S-parameter measurement:
1. As
shows, the S-parameter is typically measured using a Vector Network Analyzer (VNA). For
measuring the TRF0206-SP EVM, a 3-port VNA is recommended which can generate single-ended and
receive differential signals at the input and output ports of the EVM respectively.
2. Before connecting the RF coax cables to the EVM, you must calibrate the VNA along with the cables using a
calibration kit.
3. Make sure the frequency sweep and output power level from the VNA is set within the linear operating
range of the TRF0206-SP devices. The resolution bandwidth (RBW) and dynamic range of the VNA can be
adjusted to give optimum sweep time for the measurement.
4. It is important to account for board trace losses at the input and output side of the device during gain
gives typical input and output trace losses measured on the EVM.
Test Setup Diagrams
8
TRF0206-SP Evaluation Module
SLAU877 – OCTOBER 2022