Texas Instruments TPS65987-90 User Manual Download Page 11

GND

GND

GND

3

1

2

Q5

22µF

C31

10µF

C42

3

1

2

4

5

V+

V-

U6

3

1

2

Q6

GND

GND

10µF

C40

GND

10µF

C41

22µF

C30

GND

DRAIN1

DRAIN2

SYS_PWR

GND

LDO_3V3

LDO_1V8

P5V0

10µF

C38

10µF

C37

GND

GND

P3V3

PP_HV1

GND

VBUS

VBUS

GND

GND

PP_EXT2_EN

LDO_3V3

GND

3

1

2

Q5

22µF

C31

3

1

2

4

5

V+

V-

V-

U6

3

1

2

Q6

GND

22µF

C30

GND

SYS_PWR

VBUS

GND

GND

PP_EXT2_EN

LDO_3V3

External Power Path (PD Controller )

GND

GND

10µF

C42

GND

10µF

C40

GND

10µF

C41

DRAIN1

DRAIN2

GND

LDO_3V3

LDO_1V8

P5V0

10µF

C38

10µF

C37

GND

GND

P3V3

PP_HV1

GND

VBUS

USB PD Power Path

VAR_DCDC

PP_CAB_87

22µF

C39

GND

PP_HV2

White

1

2

D16

GND

0.1µF

C35

100k

R62

DNP

10.0k

R66

10.0k

R60

10.0k

R57

10.0k

R55

1.00k

R61

10.0k

R54

DNP

10.0k

R56

DNP

576k

R65

0.1µF

C34

DNP

0.1µF

C33

1µF

C36

2

1

7,8

Q4A

4

3

5,6

Q4B

60.4k

R59

60.4k

R58

10.0k

R63

10.0k

R64

0.1µF

C32

0

R52

DNP

0

R53

0

R67

DNP

0

R68

DNP

GND

0

R131

P3V3

LDO_1V8

35

LDO_3V3

9

DRAIN1

15

PP1_CABLE

25

GND

46

PP_HV1

12

PP_HV1

11

PP_HV2

1

PP_HV2

2

VBUS1

13

VBUS1

14

VBUS2

3

VBUS2

4

VIN_3V3

5

DRAIN2

56

DRAIN2

57

DRAIN2

7

DRAIN1

8

DRAIN1

19

DRAIN1

58

DRAIN2

52

GND

51

GND

20

GND

59

TPS65987DDHRSHR

U4B

www.ti.com

Schematic

11

SLVUBF3A – May 2018 – Revised August 2018

Submit Documentation Feedback

Copyright © 2018, Texas Instruments Incorporated

TPS65987-90 Evaluation Module

Figure 7. USB PD Power Paths

Summary of Contents for TPS65987-90

Page 1: ...matic 8 5 Bill of Materials 14 List of Figures 1 TPS65987 90EVM Board 2 2 TPS65987 90EVM Block Level Diagram 3 3 Power Path Jumper Configuration for Source or Sink 4 4 USB Type C and DP Expansion Pack...

Page 2: ...pon cable detection the TPS65987 communicates on the CC wire using the USB PD protocol When cable detection and USB PD negotiation are complete the TPS65987 device enables the appropriate power path a...

Page 3: ...n 3 SLVUBF3A May 2018 Revised August 2018 Submit Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS65987 90 Evaluation Module Figure 2 TPS65987 90EVM Block Level Diagram 1 1 Item...

Page 4: ...d PPHV2 as source path J6 which matches the configuration of firmware already programmed in the device Using Application Customization Tool each of this power path can be programmed as either source o...

Page 5: ...f 3 3 V DC DC convertor to power up all ICs on the EVM TP7 P5V0 Output of 5 V DC DC convertor used for PP_CABLE VCONN 2 4 LEDs Table 4 lists the TPS65987 90EVM LEDs 1 On the EVM board silkscreen print...

Page 6: ...the OFF position to the left 5 I2C_SCL Connects I2C_SCL node from FTDI to TPS65987D EEPROM when the switch is in the ON position to the right and disconnects when in the OFF position to the left 6 I2C...

Page 7: ...a single port laptop computer This configuration can be used to source or sink power known as DRP and this configuration sets DFP_D Downward Facing Port on DP expansion connector a DP_EXPANSION source...

Page 8: ...AR_DCDC P5V0 P3V3 C_USB_P C_USB_N GPIO_5 I2C3_SCL GPIO_6 I2C3_SDA I2C_SCL_SAM I2C_SCL_SAM I2C_SDA_SAM I2C_SDA_SAM DP Expansion Pack Connector 4 7 F C1 3 48 R1 SSMX_USB3 SSMX_FLIP SSMX_DP I2C1_IRQZ GPI...

Page 9: ...ADBUS4 21 ADBUS5 22 ADBUS6 23 ADBUS7 24 BDBUS0 26 BDBUS1 27 BDBUS3 29 BDBUS2 28 BDBUS4 30 BDBUS5 32 BDBUS6 33 BDBUS7 34 CDBUS0 38 CDBUS1 39 CDBUS2 40 CDBUS3 41 CDBUS4 43 CDBUS5 44 CDBUS6 45 CDBUS7 46...

Page 10: ...ematic www ti com 10 SLVUBF3A May 2018 Revised August 2018 Submit Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS65987 90 Evaluation Module Figure 6 USB PD Controller and Memo...

Page 11: ...2 F C39 GND PP_HV2 White 1 2 D16 GND 0 1 F C35 100k R62 DNP 10 0k R66 10 0k R60 10 0k R57 10 0k R55 1 00k R61 10 0k R54 DNP 10 0k R56 DNP 576k R65 0 1 F C34 DNP 0 1 F C33 1 F C36 2 1 7 8 Q4A 4 3 5 6 Q...

Page 12: ...WR GND EN_VAR EN_VAR EN_VAR GND 10k R104 30k R100 GND 9 53k R107 0 1 F C56 Green 2 1 D20 8 87k R111 1 2 3 Q11 1 2 3 Q12 1 2 3 Q13 1 2 3 Q14 3 65k R112 47 F C50 47 F C51 VAR_DCDC EN_VAR EN_VAR EN_VAR P...

Page 13: ...A 2 2 H L4 0 1 F C79 GND 22 F C75 VIN 1 VSENSE 6 EN 8 PGOOD 10 GND 3 COMP 7 PH 2 BOOT 9 PAD 11 GND 4 GND 5 U10 TPS54334DRCR 300pF C82 2 61k R124 6800pF C83 GND PGD_3V3 GND 47 F C88 100k R122 32 4k R12...

Page 14: ...4 7 uF 10 V 20 X5R 0402 0402 C1005X5R1A475M050BC TDK C23 C24 2 27pF CAP CERM 27 pF 50 V 1 C0G NP0 0603 0603 CL10C270FB8NNNC Samsung Electro Mechanics C25 1 0 01uF CAP CERM 0 01 F 50 V 5 X7R 0402 0402...

Page 15: ...SMD 7343 43 TAJE476M035RNJ AVX C54 1 0 1uF CAP CERM 0 1 F 50 V 10 X7R 0402 0402 C1005X7R1H104K050BB TDK C55 C58 2 1000pF CAP CERM 1000 pF 50 V 20 X7R 0402 0402 C1005X7R1H102M050BE TDK C56 C73 2 0 1uF...

Page 16: ...x 0 5 L 4 40 Nylon Standoff 1902C Keystone J1 1 Connector Receptacle USB Type C R A SMT Connector Receptacle USB Type C SMT 20 0000016 01 Lintes Technology J2 1 Socket 0 8mm 20x2 Gold SMT Socket 0 8mm...

Page 17: ...onductor None R1 1 3 48 RES 3 48 1 0 063 W 0402 0402 CRCW04023R48FKED Vishay Dale R2 R3 R4 R5 4 0 RES 0 5 0 05 W 0201 0201 CRCW02010000Z0ED Vishay Dale R6 R8 R10 3 0 RES 0 5 0 063 W 0402 0402 ERJ 2GE0...

Page 18: ...CW040247K5FKED Vishay Dale R100 1 30k RES 30 k 5 0 063 W 0402 0402 CRCW040230K0JNED Vishay Dale R103 1 270 RES 270 5 0 063 W 0402 0402 CRCW0402270RJNED Vishay Dale R104 1 10k RES 10 k 5 0 1 W 0603 060...

Page 19: ...Comparator DBV0005A DBV0005A TLV1701AIDBVR Texas Instruments TLV1701AIDBVT Texas Instruments U8 1 22 V Precision Surge Protection Clamp DRV0006A WSON 6 DRV0006A TVS2200DRVR Texas Instruments Texas In...

Page 20: ...Alternate PartNumber Alternate Manufacturer R52 R98 0 0 RES 0 5 0 125 W 0805 0805 ERJ 6GEY0R00V Panasonic R54 R56 0 10 0k RES 10 0 k 1 0 1 W 0402 0402 ERJ 2RKF1002X Panasonic R62 0 100k RES 100 k 1 0...

Page 21: ...set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that...

Page 22: ...the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain great...

Page 23: ...t the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the...

Page 24: ...OST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF...

Page 25: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Reviews: