Table 2. TPS65313-EVM Jumper Settings
Jumper
Number
Jumper Name
Jumper Description
Default Jumper Settings
J1
VBUCK1_EXT
Filtered BUCK1 output connector
Not applicable
J2
VBUCK2_EXT
Filtered BUCK2 output connector
Not applicable
J3
VBOOST_EXT
Filtered BOOST output connector
Not applicable
J4
VBAT
V
BAT
supply and PGND connector
Not applicable
J5
VSUP
Input supply for BUCK2 and BOOST coming
from V
BUCK1
Jumpers between J5_1_2 and J5_3_4 for the
BUCK2 supply
Jumpers between J5_7_8 and J5_9_10 for the
BOOST supply
J6
VIO
IO supply for SPI
Jumper between J6_7_8 (+5V_EXT) from the
USB interface
J7
NRES
System reset output
Jumper between J7_1_2
J8
ENDRV
Enable drive output
Jumper between J8_1_2
J9
DIAGOUT
Diagnostic output
Jumper between J9_2_3
J10
SYNC_IN
PLL input clock. The onboard 2.3-MHz clock
generated using the LMC555 timer can be used
to sync the device this external clock
Jumper between J10_2_3
J11
MCUERR
MCU error pin monitor
Jumper between J11_2_3
J12
CSN
SPI: Chip select input
Use jumper between J10_1_2
J13
EXT_SENSE1
External general-purpose voltage monitor input
1
Jumper between J13_1_2
J14
EXT_SENSE2
External general-purpose voltage monitor input
2
Jumper between J14_1_2
J15
EXTSUP
External supply for VREG
Jumper between J13_1_2 for connecting the
BOOST pin to the EXTSUP pin
J16
SCLK
SPI: Clock input
Jumper between J14_1_2
J17
SDO
SPI: SPI Slave data output (push-pull output)
Jumper between J15_1_2
J18
SDI
SPI: SPI Slave data input
Jumper between J16_1_2
J19
J17
Not applicable
Not applicable
J20
J20
Wake input options:
J20_1_2: WAKE from VBAT through S2 switch
J20_2_3: WAKE from USB
Jumper between J20_1_2: WAKE from VBAT
through S2
J21
VBAT_INT
Supply for
WAKE from USB
circuit
Jumper between J21_1_2
J22
J22
Supply for external clock generator circuit
Jumper between J22_1_2
J23
CLK_WD
External clock generator circuit frequency
setting
Not applicable
J24
J24
Not applicable
Not applicable
J25
PUR VUSB
Not applicable
No jumper, keep this pin open
J26
J26
USB port
Connect this port to USB port of the PC
J27
J27
Device configuration change control signal 1
Jumper between J27_1_2. This jumper is
needed only for changing device configuration.
J28
J28
Device configuration change control signal 2
Jumper between J28_1_2. This jumper is
needed only for changing device configuration.
J29
J29
Not applicable
Not applicable