5.3 Equipment Set Up Procedure
is the recommended test setup to evaluate the TPS56121EVM-601.
T
I
EXAS
NSTRUMENTS
LOAD
1.0V @
15A
-
+
FAN
V2
-
+
A1
-
+
DC
source
V
IN
V1
-
+
Figure 5-1. TPS56121EVM-601 Recommended Test Setup
1. Working at an ESD workstation, make sure that any wrist straps, bootstraps and mats are connected
referencing the user to earth ground before power is applied to the EVM. Wearing electrostatic smock and
safety glasses is also recommended.
2. Prior to connecting the DC input source, VIN, it is advisable to limit the source current from VIN to 3.0 A
maximum. Make sure VIN is initially set to 0 V and connected as shown in
.
3. Connect VIN to J1 as shown in
.
4. Connect ammeter A1 between VIN and J1 as shown in
5. Connect voltmeter V1 to TP1 and TP2 as shown in
6. Connect voltmeter V2 to TP3 and TP4 as shown in
7. Place the fan as shown in
and turn it on, ensuring that the air blows directly across the evaluation
module.
Test Setup
8
TPS56121 Step-Down Converter Evaluation Module User's Guide
SLVU445C – MARCH 2011 – REVISED AUGUST 2021
Copyright © 2021 Texas Instruments Incorporated