background image

STANDARD TERMS FOR EVALUATION MODULES

1.

Delivery:

TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or

documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.

1.1

EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software

1.2

EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.

2

Limited Warranty and Related Remedies/Disclaimers

:

2.1

These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.

2.2

TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques

are

used

to

the

extent

TI

deems

necessary.

TI

does

not

test

all

parameters

of

each

EVM.

User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.

2.3

TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.

WARNING

Evaluation Kits are intended solely for use by technically qualified,

professional electronics experts who are familiar with the dangers

and application risks associated with handling electrical mechanical

components, systems, and subsystems.

User shall operate the Evaluation Kit within TI’s recommended

guidelines and any applicable legal or environmental requirements

as well as reasonable and customary safeguards. Failure to set up

and/or operate the Evaluation Kit within TI’s recommended

guidelines may result in personal injury or death or property

damage. Proper set up entails following TI’s instructions for

electrical ratings of interface circuits such as input, output and

electrical loads.

NOTE:

EXPOSURE TO ELECTROSTATIC DISCHARGE (ESD) MAY CAUSE DEGREDATION OR FAILURE OF THE EVALUATION
KIT; TI RECOMMENDS STORAGE OF THE EVALUATION KIT IN A PROTECTIVE ESD BAG.

Summary of Contents for TPS552882EVM-2MHz

Page 1: ...d Test Point Descriptions 2 2 2 Jumper Configuration 2 3 Test Procedure 3 4 Schematic Bill of Materials and Board Layout 3 4 1 Schematic 4 4 2 Bill of Materials 5 4 3 Board Layout 7 5 Revision History 10 List of Figures Figure 4 1 TPS552882EVM 2MHz Schematic 4 Figure 4 2 TPS552882EVM 2MHz Top Side Layout 7 Figure 4 3 TPS552882EVM 2MHz Inner Layer1 8 Figure 4 4 TPS552882EVM 2MHz Inner Layer2 9 Figu...

Page 2: ...onnector and Test Point Descriptions This EVM includes I O connectors and test points as shown in Table 2 1 The power supply must be connected to input connectors J1 and J2 The load must be connected to output connectors J3 and J4 Table 2 1 Connectors and Test Points Reference Designator Description J1 Input voltage positive connection J2 Input voltage return connection J3 Output voltage connectio...

Page 3: ...t must remain in regulation when the load current is lower than 3 A 5 Slowly sweep the input voltage from 5 V to 20 V The output voltage must remain in regulation when the load current is lower than the maximum load current specified in Table 2 1 6 Turn off the load turn off the power supply Then turn on the load to discharge the output capacitors 4 Schematic Bill of Materials and Board Layout Thi...

Page 4: ...tic Figure 4 1 TPS552882EVM 2MHz Schematic Schematic Bill of Materials and Board Layout www ti com 4 TPS552882EVM 2MHz Evaluation Module SLVUBW5A JUNE 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 5: ...ons JP1 1 Header 100mil 3x1 Tin TH Header 3 PIN 100mil Tin PEC03SAAN Sullins Connector Solutions L1 1 1uH Inductor Shielded Composite 1 µH 18 A 0 00618 ohm AEC Q200 Grade 1 SMD IND_6 4x3 1x6 6 XAL6030 102MEB Coilcraft Q1 Q2 2 NPN LO RA 150 MM PGTL M12 TSDSON 8 IPZ40N04S5L7R4ATMA1 Infineon R1 R14 R15 R16 4 102k RES 102 k 1 0 063 W AEC Q200 Grade 0 0402 0402 CRCW0402102KFKED Vishay Dale R2 1 11 3k R...

Page 6: ...oost Converter VQFN HR26 TPS552882RPM Texas Instruments C21 0 Multilayer Ceramic Capacitors MLCC 470pF 100V 0603 0603 GRT1885C2A471JA02D Murata C22 0 680pF 5 100V Ceramic Capacitor C0G 0603 1608 Metric 0603 GRT1885C2A681JA02D Murata R17 R18 0 1 0 RES 1 0 5 0 5 W 1206 1206 CRM1206 JW 1R0ELF Bourns Schematic Bill of Materials and Board Layout www ti com 6 TPS552882EVM 2MHz Evaluation Module SLVUBW5A...

Page 7: ...M board layouts Figure 4 2 TPS552882EVM 2MHz Top Side Layout www ti com Schematic Bill of Materials and Board Layout SLVUBW5A JUNE 2020 REVISED OCTOBER 2020 Submit Document Feedback TPS552882EVM 2MHz Evaluation Module 7 Copyright 2020 Texas Instruments Incorporated ...

Page 8: ...M 2MHz Inner Layer1 Schematic Bill of Materials and Board Layout www ti com 8 TPS552882EVM 2MHz Evaluation Module SLVUBW5A JUNE 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 9: ...M 2MHz Inner Layer2 www ti com Schematic Bill of Materials and Board Layout SLVUBW5A JUNE 2020 REVISED OCTOBER 2020 Submit Document Feedback TPS552882EVM 2MHz Evaluation Module 9 Copyright 2020 Texas Instruments Incorporated ...

Page 10: ...evision December 2020 to Revision A October 2020 Page Updated the numbering format for tables figures and cross references throughout the document 2 Changed all images in the Board Layout section 7 Revision History www ti com 10 TPS552882EVM 2MHz Evaluation Module SLVUBW5A JUNE 2020 REVISED OCTOBER 2020 Submit Document Feedback Copyright 2020 Texas Instruments Incorporated ...

Page 11: ...other than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control techniques are used to the extent TI deems necessary TI does not test all parameters of each EVM User s claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects...

Page 12: ... These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 13: ...y for convenience and should be verified by User 1 Use EVMs in a shielded room or any other test facility as defined in the notification 173 issued by Ministry of Internal Affairs and Communications on March 28 2006 based on Sub section 1 1 of Article 6 of the Ministry s Rule for Enforcement of Radio Law of Japan 2 Use EVMs only after User obtains the license of Test Radio Station as provided in R...

Page 14: ... any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard User assumes all responsibility and liability for any improper or unsafe handling or use of the EVM by User or its employees affiliates contractors or designees 4 4 User assumes all...

Page 15: ...OR DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthermore no return of EVM s will be accepted if the package has been opened and no return of the EVM s will be accepted if they are damaged or otherwise not in a resalable condition If User feels it has...

Page 16: ...se resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of these resources is prohibited No license is granted to any other TI intellectual property right or to any third party intellectual property right TI disclaims responsibility for...

Reviews: