Network
Analyzer
Isolation
Transformer
LOAD1
1.2V @
20A
+
-
V2
-
+
See Tip and Barrel
Measurement for
Vout ripple
V1
+
-
A1
-
+
V
IN
Oscilloscope
1M
W
, AC
20mV / div
20MHz
Test Setup
9
SNVU588 – November 2017
Copyright © 2017, Texas Instruments Incorporated
TPS40345EVM-353 Evaluation Module
Figure 4. Control Loop Measurement Setup
5.3
Start-Up/Shutdown Procedure
1. Verify shunt position for JP1 for desired FSS status per
_________(need correct reference)
.
2. Remove shunt from JP2 location if present.
3. Increase V
IN
from 0 Vdc to 12 Vdc.
4. Vary LOAD1 from 0 Adc to 20 Adc.
5. Vary V
IN
from 8 V to 14 V.
6. Decrease V
IN
to 0 V.
7. Decrease LOAD1 to 0 A.
5.4
Output Ripple Voltage Measurement Procedure
1. Follow
steps 1 – 5 to set V
IN
and LOAD1 to the desired operating condition.
2. Connect oscilloscope probe with exposed metal barrel to TP3 and TP4 per
.
3. Set oscilloscope per oscilloscope for output voltage ripple measurement in
.
4. Follow
steps 6 and 7 to power down.
5.5
Control Loop Gain and Phase Measurement Procedure
1. Follow
steps 1 – 5 to set V
IN
and LOAD1 to the desired operating condition:
a. If JP1 is installed (FSS enabled), loop response data about the modulation frequency (30 kHz)
may be affected.
2. Connect a 1-kHz – 1-MHz isolation transformer to TP5 and TP7 as shown in
.