5.2 Equipment Setup
Shown in
is the basic test setup recommended to evaluate the TPS40195EVM. Please note that
although the return for J1 and J4 are the same, the connections should remain separate as shown in
1. Working at an ESD workstation, make sure that any wrist straps, bootstraps, or mats are connected
referencing the user to earth ground before power is applied to the EVM. Electrostatic smock and safety
glasses should also be worn.
2. Prior to connecting the DC input source, V
IN
, it is advisable to limit the source current from V
IN
to 20-A
maximum. Make sure V
IN
is initially set to 0 V and connected as shown in
3. Connect the ammeter A1 (0-A to 20-A range) between V
IN
and J1 as shown in
.
4. Connect voltmeter V1 to TP1 and TP2 as shown in
5. Connect LOAD1 to J3 and J4 as shown in
. Set LOAD1 to constant current mode to sink 0 A
DC
before V
IN
is applied.
6. Connect voltmeter, V2 across TP5 and TP6 as shown in
.
7. Place Fan as shown in
and turn on, making sure air is flowing across the EVM.
.
Oscilloscop
e
1M
W
, AC
20MHz
See figure 3 for tip
and barrel
measurement
3.3V
0 to 20A
LOAD1
+
-
V2
+
-
V1
+
-
0 to 20V
V
IN
-
+
A1
FAN
Figure 5-1. TPS40195EVM Recommended Test Setup