![Texas Instruments TPS26630-33EVM User Manual Download Page 2](http://html.mh-extra.com/html/texas-instruments/tps26630-33evm/tps26630-33evm_user-manual_1096944002.webp)
Introduction
2
SLVUBI8A – October 2018 – Revised March 2019
Copyright © 2018–2019, Texas Instruments Incorporated
TPS26630-33EVM: Evaluation Module for TPS2663x
11
TPS26630-33EVM Output Short-Circuit Protection Test
.............................................................
12
TPS26630-33EVM Bill of Materials
......................................................................................
Trademarks
All trademarks are the property of their respective owners.
1
Introduction
The TPS26630-33EVM allows reference circuit evaluation of TI's TPS2663x eFuse devices. The
TPS2663x are 4.5-V to 60-V, 0.6-A to 6-A industrial eFuses with integrated 31-m
Ω
FET, programmable
undervoltage, overvoltage, reverse-polarity protection with external N-channel FET driver, overcurrent,
inrush current protection and output current monitoring features. It features a blocking FET driver that
controls an external N-channel FET for input reverse polarity protection and reverses current blocking.
1.1
REACH Compliance
In compliance with the Article 33 provision of the EU REACH regulation, we are notifying you that this
EVM includes a component containing at least one substance of very high concern (SVHC) above 0.1%.
These uses from Texas Instruments do not exceed 1 ton per year. The SVHC summary is listed in
Table 1. SVHC Summary
Component Manufacturer
Component type
Component part
number
SVHC
Substance
SVHC CAS (when
available)
Diodes Inc.
Diode
SMCJ33CA-13-F
Lead
7439-92-1
1.2
EVM Features
The TPS26630-33EVM features include:
•
4.5-V to 60-V input operating voltage range
•
0.6-A to 6-A programmable current limit
•
Reverse polarity protection up to –60 V with external N-Channel MOSFET
•
Output Power Limiting Scheme (PLIM)
•
Load protection from Surge and EFT (IEC61000-4-5 Level 1 and IEC61000-4-4 Level 3).
•
Programmable input UVLO and OVP cut off – 18 V and 33 V respectively
•
Fixed Overvoltage Clamp (Channel 2 only) – 35-V fixed
•
Programmable V
OUT
slew rate control
•
Selectable Overcurrent fault response (Auto-Retry and Latch)
•
Optional on-board transient protection devices like input TVS and output Schottky diodes
•
33-V SMC TVS for surge protection
•
On-board reset switch and fault indicators
1.3
Applications
•
PLC, CNC
•
Medical Equipment
•
Control and Automation
•
Industrial power systems
•
Sensors Hubs