Test Procedure and Results
8
SLVUBQ5A – August 2019 – Revised October 2019
Copyright © 2019, Texas Instruments Incorporated
TPS2663-166EVM: Evaluation Module for TPS2663xPWP and
TPS1663xPWP
6
Test Procedure and Results
6.1
Hot-plug and Start-up With 4.8
Ω
Load
Use the following instructions to measure the output slew rate and input inrush current during start-up.
•
Set the input supply voltage V
IN
to 24 V and a current limit of 10 A. Enable the power supply.
•
Connect a load of 4.8
Ω
at output connector T2 for testing CH1 and T4 for testing CH2.
•
Hot-plug the power supply at input connector T1 for testing CH1 and T3 for testing CH2.
•
Observe the waveform at V
IN
, V
OUT
, FLT, and I
IN
with an oscilloscope to measure the output slew rate
and rise time. The device starts with inrush current of 0.5 A and the output voltage reaches V
IN
in 50
ms.
and
show examples of inrush current during start-up on the TPS2663-166EVM.
Figure 3. TPS2663-166EVM Startup for CH1 (V
IN
= 24 V,
I
LIM
= 6 A, R
OUT
= 4.8
Ω
, MODE = GND)
Figure 4. TPS2663-166EVM Startup for CH2 (V
IN
= 24 V,
I
LIM
= 6 A, R
OUT
= 4.8
Ω
, MODE = GND)